Effects of 1800 MHz and 2100 MHz mobile phone radiation on the blood–brain barrier of New Zealand rabbits
Medical & Biological Engineering & Computing · 2025
DOI: 10.1007/s11517-024-03238-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2025. Verfasst von Abdullah Oğuz Kizilçay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Engineering, Zonguldak Bülent Ecevit University, Zonguldak, Turkey. Hauptthemen laut MEDLINE: Blood-Brain Barrier, Cell Phone, Radio Waves. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.
Abstract (Originalsprache)
In this study, the impact of mobile phone radiation on blood-brain barrier (BBB) permeability was investigated. A total of 21 New Zealand rabbits were used for the experiments, divided into three groups, each consisting of 7 rabbits. One group served as the control, while the other two were exposed to electromagnetic radiation at frequencies of 1800 MHz with a distance of 14.5 cm and 2100 MHz with a distance of 17 cm, maintaining a constant power intensity of 15 dBm, for a duration equivalent to the current average daily conversation time of 38 min. The exposure was conducted under non-thermal conditions, with RF radiation levels approximately ten times lower than normal values. Evans blue (EB) dye was used as a marker to assess BBB permeability. EB binds to plasma proteins, and its presence in brain tissue indicates a disruption in BBB integrity, allowing for a quantitative evaluation of radiation-induced permeability changes. Left and right brain tissue samples were analyzed using trichloroacetic acid (TCA) and phosphate-buffered solution (PBS) solutions to measure EB amounts at 620 nm via spectrophotometry. After the experiments, BBB tissue samples were collected from the right and left brains of all rabbits in the three groups and subjected to a series of medical procedures. Samples from Group 1 were compared with those from Group 2 and Group 3 using statistical methods to determine if there were any significant differences. As a result, it was found that there was no statistically significant difference in the BBB of rabbits exposed to 1800 MHz radiation, whereas there was a statistically significant difference at a 95% confidence level in the BBB of rabbits exposed to 2100 MHz radiation. A decrease in EB values was observed upon the arithmetic examination of the BBB.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Computer Engineering, Zonguldak Bülent Ecevit University, Zonguldak, Turkey.
- Energy Institute, Istanbul Technical University, Istanbul, Turkey. bilaltutuncu@itu.edu.tr.
- Department of Sterilization, Dursun Odabaş Medical Faculty, Van Yüzüncü Yıl University, Van, Turkey.
- Department of Electrical and Electronics Engineering, Süleyman Demirel University, Isparta, Turkey.
Förderung
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Zitieren
APA
Kizilçay, A. O., Tütüncü, B., Koçarslan, M., & Gözel, M. A. (2025). Effects of 1800 MHz and 2100 MHz mobile phone radiation on the blood–brain barrier of New Zealand rabbits. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-024-03238-1
Vancouver
Kizilçay AO, Tütüncü B, Koçarslan M, Gözel MA. Effects of 1800 MHz and 2100 MHz mobile phone radiation on the blood–brain barrier of New Zealand rabbits. Medical & Biological Engineering & Computing. 2025. doi:10.1007/s11517-024-03238-1
BibTeX
@article{Kizilay2025,
author = {Kizilçay, Abdullah Oğuz and Tütüncü, Bilal and Koçarslan, Mehmet and Gözel, Mahmut Ahmet},
title = {Effects of 1800 MHz and 2100 MHz mobile phone radiation on the blood–brain barrier of New Zealand rabbits},
journal = {Medical & Biological Engineering & Computing},
year = {2025},
doi = {10.1007/s11517-024-03238-1}
}
EUVIMED