Load-bearing optimization for customized exoskeleton design based on kinematic gait reconstruction
Medical & Biological Engineering & Computing · 2025-03 · 63 (3) · 807-822
DOI: 10.1007/s11517-024-03234-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, online erschienen am 06.11.2024. Verfasst von Zhengxin Tu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Design Engineering, Zhejiang University, Hangzhou, 310058, China. Hauptthemen laut MEDLINE: Exoskeleton Device, Weight-Bearing, Gait. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben.
Abstract (Originalsprache)
This paper presents a load-bearing optimization method for customized exoskeleton design based on kinematic gait reconstruction (KGR). For people with acute joint injury, it is no longer probable to obtain the movement gait via computer vision. With this in mind, the 3D reconstruction can be executed from the CT (computed tomography) or MRI (magnetic resonance imaging) of the injured area, in order to generate micro-morphology of the joint occlusion. Innovatively, the disconnected entities can be registered into a whole by surface topography matching with semi-definite computing, further implementing KGR by rebuilding continuous kinematic skeletal flexion postures. To verify the effectiveness of reconstructed kinematic gait, finite element analysis (FEA) is conducted via Hertz contact theory. The lower limb exoskeleton is taken as a verification instance, where rod length ratio and angular rotation range can be set as the design considerations, so as to optimize the load-bearing parameters, which is suitable for individual kinematic gaits. The instance demonstrates that the proposed KGR helps to provide a design paradigm for optimizing load-bearing capacity, on the basis of which the ergonomic customized exoskeleton can be designed from merely medical images, thereby making it more suitable for the large rehabilitation population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Design Engineering, Zhejiang University, Hangzhou, 310058, China.
- State Key Lab of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310058, China. xujh@zju.edu.cn.
- State Key Lab of Mechanical Transmissions, Chongqing University, Chongqing, 400044, China. xujh@zju.edu.cn.
- Zhejiang Key Lab of Advanced Manufacturing Technology, Zhejiang University, Hangzhou, 310058, China. xujh@zju.edu.cn.
- Institute of Design Engineering, Zhejiang University, Hangzhou, 310058, China. xujh@zju.edu.cn.
- Qingdao Huangdao District People's Hospital, Qingdao, 266400, China.
Zitieren
APA
Tu, Z., Xu, J., Dong, Z., Zhang, S., & Tan, J. (2025). Load-bearing optimization for customized exoskeleton design based on kinematic gait reconstruction. Medical & Biological Engineering & Computing, 63(3), 807-822. https://doi.org/10.1007/s11517-024-03234-5
Vancouver
Tu Z, Xu J, Dong Z, Zhang S, Tan J. Load-bearing optimization for customized exoskeleton design based on kinematic gait reconstruction. Medical & Biological Engineering & Computing. 2025;63(3):807-822. doi:10.1007/s11517-024-03234-5
BibTeX
@article{Tu2025,
author = {Tu, Zhengxin and Xu, Jinghua and Dong, Zhenyu and Zhang, Shuyou and Tan, Jianrong},
title = {Load-bearing optimization for customized exoskeleton design based on kinematic gait reconstruction},
journal = {Medical & Biological Engineering & Computing},
year = {2025},
volume = {63},
number = {3},
pages = {807--822},
doi = {10.1007/s11517-024-03234-5}
}
EUVIMED