Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2024. Verfasst von Chiara Bregoli und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Research Council, CNR-ICMTE, Lecco, Italy. chiara.bregoli@polimi.it. Hauptthemen laut MEDLINE: Osteoporosis, Cancellous Bone, Bone Density. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Politecnico di Milano, Consiglio Nazionale Delle Ricerche.
Abstract (Originalsprache)
Research at the mesoscale bone trabeculae arrangement yields intriguing results that, due to their clinical resolution, can be applied in clinical field, contributing significantly to the diagnosis of bone-related diseases. While the literature offers quantitative morphometric parameters for a thorough characterization of the mesoscale bone network, there is a gap in understanding relationships among them, particularly in the context of various bone pathologies. This research aims to bridge these gaps by offering a quantitative evaluation of the interplay among morphometric parameters and mechanical response at mesoscale in osteoporotic and non-osteoporotic bones. Bone mechanical response, dependent on trabecular arrangement, is defined by apparent stiffness, computationally calculated using the Gibson-Ashby model. Key findings indicate that: (i) in addition to bone density, measured using X-ray absorptiometry, trabecular connectivity density, trabecular spacing and degree of anisotropy are crucial parameters for characterize osteoporosis state; (ii) apparent stiffness values exhibit strong correlations with bone density and connectivity density; (iii) connectivity density and degree of anisotropy result the best predictors of mechanical response. Despite the inherent heterogeneity in bone structure, suggesting the potential benefit of a larger sample size in the future, this approach presents a valuable method to enhance discrimination between osteoporotic and non-osteoporotic samples. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Research Council, CNR-ICMTE, Lecco, Italy. chiara.bregoli@polimi.it.
- Mechanical Engineering Department, Politecnico Di Milano, Milano, Italy. chiara.bregoli@polimi.it.
- National Research Council, CNR-ICMTE, Lecco, Italy.
- Mechanical Engineering Department, Politecnico Di Milano, Milano, Italy.
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
Förderung
- Politecnico di Milano
- Consiglio Nazionale Delle Ricerche
Zitieren
APA
Bregoli, C., Biffi, C. A., Tuissi, A., & Buccino, F. (2024). Effect of trabecular architectures on the mechanical response in osteoporotic and healthy human bone. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-024-03134-8
Vancouver
Bregoli C, Biffi CA, Tuissi A, Buccino F. Effect of trabecular architectures on the mechanical response in osteoporotic and healthy human bone. Medical & Biological Engineering & Computing. 2024. doi:10.1007/s11517-024-03134-8
BibTeX
@article{Bregoli2024,
author = {Bregoli, Chiara and Biffi, Carlo Alberto and Tuissi, Ausonio and Buccino, Federica},
title = {Effect of trabecular architectures on the mechanical response in osteoporotic and healthy human bone},
journal = {Medical & Biological Engineering & Computing},
year = {2024},
doi = {10.1007/s11517-024-03134-8}
}
EUVIMED