Improved recovery of cardiac auscultation sounds using modified cosine transform and LSTM-based masking
Medical & Biological Engineering & Computing · 2024
DOI: 10.1007/s11517-024-03088-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2024. Verfasst von Awad Al-Zaben und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Department, Engineering Faculty, Hashemite University, Zarqa, Jordan. azaben@yu.edu.jo. Hauptthemen laut MEDLINE: Heart Auscultation, Heart Sounds, Signal Processing, Computer-Assisted, Algorithms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 44 Literaturangaben.
Abstract (Originalsprache)
Obtaining accurate cardiac auscultation signals, including basic heart sounds (S1 and S2) and subtle signs of disease, is crucial for improving cardiac diagnoses and making the most of telehealth. This research paper introduces an innovative approach that utilizes a modified cosine transform (MCT) and a masking strategy based on long short-term memory (LSTM) to effectively distinguish heart sounds and murmurs from background noise and interfering sounds. The MCT is used to capture the repeated pattern of the heart sounds, while the LSTMs are trained to construct masking based on the repeated MCT spectrum. The proposed strategy's performance in maintaining the clinical relevance of heart sounds continues to demonstrate effectiveness, even in environments marked by increased noise and complex disruptions. The present work highlights the clinical significance and reliability of the suggested methodology through in-depth signal visualization and rigorous statistical performance evaluations. In comparative assessments, the proposed approach has demonstrated superior performance compared to recent algorithms, such as LU-Net and PC-DAE. Furthermore, the system's adaptability to various datasets enhances its reliability and practicality. The suggested method is a potential way to improve the accuracy of cardiovascular diagnostics in an era of rapid advancement in medical signal processing. The proposed approach showed an enhancement in the average signal-to-noise ratio (SNR) by 9.6 dB at an input SNR of - 6 dB and by 3.3 dB at an input SNR of 10 dB. The average signal distortion ratio (SDR) achieved across a variety of input SNR values was 8.56 dB.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering Department, Engineering Faculty, Hashemite University, Zarqa, Jordan. azaben@yu.edu.jo.
- Biomedical Systems and Medical Informatics Department, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan. azaben@yu.edu.jo.
- Biomedical Systems and Medical Informatics Department, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan.
- Faculty of Medicine, Interventional Cardiologist, Jordan University of Science and Technology, Irbid, Jordan.
- Biomedical Engineering Department, Engineering Faculty, Hashemite University, Zarqa, Jordan.
Zitieren
APA
Al-Zaben, A., Al-Fahoum, A., Ababneh, M., Al-Naami, B., & Al-Omari, G. (2024). Improved recovery of cardiac auscultation sounds using modified cosine transform and LSTM-based masking. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-024-03088-x
Vancouver
Al-Zaben A, Al-Fahoum A, Ababneh M, Al-Naami B, Al-Omari G. Improved recovery of cardiac auscultation sounds using modified cosine transform and LSTM-based masking. Medical & Biological Engineering & Computing. 2024. doi:10.1007/s11517-024-03088-x
BibTeX
@article{AlZaben2024,
author = {Al-Zaben, Awad and Al-Fahoum, Amjad and Ababneh, Muhannad and Al-Naami, Bassam and Al-Omari, Ghadeer},
title = {Improved recovery of cardiac auscultation sounds using modified cosine transform and LSTM-based masking},
journal = {Medical & Biological Engineering & Computing},
year = {2024},
doi = {10.1007/s11517-024-03088-x}
}