Study on mechanical properties of dual-channel cryogenic 3D printing scaffold for mandibular defect repair
Medical & Biological Engineering & Computing · 2024
DOI: 10.1007/s11517-024-03079-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2024. Verfasst von Lilan Gao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Techno…. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Tissue Scaffolds, Mandible, Finite Element Analysis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Tianjin Municipality, Technical Innovation Guidance Project of Tianjin Science and Technology Bureau.
Abstract (Originalsprache)
Mandibular defect repair has always been a clinical challenge, facing technical bottleneck. The new materials directly affect technological breakthroughs in mandibular defect repair field. Our aim is to fabricate a scaffold of advanced biomaterials for repairing of small mandibular defect. Therefore, a novel dual-channel scaffold consisting of silk fibroin/collagen type-I/hydroxyapatite (SCH) and polycaprolactone/hydroxyapatite (PCL/HA) was fabricated by cryogenic 3D printing technology with double nozzles. The mechanical properties and behaviors of the dual-channel scaffold were investigated by performing uniaxial compression, creep, stress relaxation, and ratcheting experiments respectively. The experiments indicated that the dual-channel scaffold was typical non-linear viscoelastic consistent with cancellous tissue; the Young's modulus of this scaffold was 60.1 kPa. Finite element analysis (FEA) was employed performing a numerical simulation to evaluate the implantation effect in mandible. The stress distribution of the contact area between scaffold and defect was uniform, the maximum Mises stress of cortical bone and cancellous bone in defect area were 54.520 MPa and 3.196 MPa, and the maximum displacement of cortical bone and cancellous bone in defect area were 0.1575 mm and 0.1555 mm respectively, which distributed in the incisor region. The peak maximum Mises stress experienced by the implanted scaffold was 3.128 × 10-3 MPa, and the maximum displacement was 6.453 × 10-2 mm distributed near incisor area. The displacement distribution of the scaffold was consistent with that of cortical and cancellous bone. The scaffold recovered well when the force applied on it disappeared. Above all, the dual-channel scaffold had excellent bio-mechanical properties in implanting mandible, which provides a new idea for the reconstruction of irregular bone defects in the mandible and has good clinical development prospects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, 300384, China.
- National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin, 300384, China.
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, 300384, China. liujiejane@163.com.
- National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin, 300384, China. liujiejane@163.com.
- Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction, Tianjin Stomatological Hospital, The Affiliated Stomatological Hospital of Nankai University, Tianjin, 300041, China. limxinxin@163.com.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Tianjin Municipality
- Technical Innovation Guidance Project of Tianjin Science and Technology Bureau
Zitieren
APA
Gao, L., Sun, M., Liu, J., Meng, L., Liu, H., & Li, R. (2024). Study on mechanical properties of dual-channel cryogenic 3D printing scaffold for mandibular defect repair. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-024-03079-y
Vancouver
Gao L, Sun M, Liu J, Meng L, Liu H, Li R. Study on mechanical properties of dual-channel cryogenic 3D printing scaffold for mandibular defect repair. Medical & Biological Engineering & Computing. 2024. doi:10.1007/s11517-024-03079-y
BibTeX
@article{Gao2024,
author = {Gao, Lilan and Sun, Mengchao and Liu, Jie and Meng, Lulu and Liu, Han and Li, Ruixin},
title = {Study on mechanical properties of dual-channel cryogenic 3D printing scaffold for mandibular defect repair},
journal = {Medical & Biological Engineering & Computing},
year = {2024},
doi = {10.1007/s11517-024-03079-y}
}
EUVIMED