EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Exploring Humerus Bone’s Fracture Patterns and Fixation Systems Via Laser Vibrometry

B. Carboni, S. K. Guruva, S. Gumina, V. Candela, J. Tirilló, C. Sergi, T. Valente, W. Lacarbonara

Experimental Mechanics · 2025-09 · 65 (7) · 1117-1132

DOI: 10.1007/s11340-025-01198-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Experimental Mechanics, online erschienen am 02.06.2025. Verfasst von B. Carboni und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sapienza Università di Roma.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The mechanical performance assessment of orthopedic fixation systems is computationally and experimentally challenging due to the complex geometrical and mechanical features of bones. Non-contact experimental techniques, widely adopted in several engineering fields, is shown to overcome these issues.

Objective

This work discusses a comparative experimental investigation into specimens mimicking healthy humerus bones and fractured bones subject to an innovative surgery procedure and to a classical technique referred to as the gold standard surgery. The new surgery consists in the installation of an external fixation mechanism that constrains, according to different spatial patterns, a certain number of titanium slender bars inserted and clamped into the fractured bones.

Methods

The mechanical properties of artificial bones are characterized through compressive tests, while the morphology of the fracture surface is analyzed using a scanning electron microscope. A three-dimensional laser vibrometer is used to measure the resonance frequencies, mode shapes, damping ratios, and mechanical waves propagating from the actuators across the surface of the bones.

Results

The results provide insights into which configuration of the fixator performs better for a fast recovery. Based on the observed dynamic behaviors, the optimal configuration of the fixator offers performance that is comparable to, or potentially better than, the gold standard surgical procedure.

Conclusions

The novelty and feasibility of the adopted experimental approach paves the way towards the adoption of advanced non-contact techniques for the mechanical characterization of complex, non-homegenous and anisotropic materials and structures in biomedical applications enabling also data-driven models of the systems.

Förderung

  • Sapienza Università di Roma

Zitieren

APA

Carboni, B., Guruva, S. K., Gumina, S., Candela, V., Tirilló, J., Sergi, C., Valente, T., & Lacarbonara, W. (2025). Exploring Humerus Bone’s Fracture Patterns and Fixation Systems Via Laser Vibrometry. Experimental Mechanics, 65(7), 1117-1132. https://doi.org/10.1007/s11340-025-01198-7

Vancouver

Carboni B, Guruva SK, Gumina S, Candela V, Tirilló J, Sergi C, et al. Exploring Humerus Bone’s Fracture Patterns and Fixation Systems Via Laser Vibrometry. Experimental Mechanics. 2025;65(7):1117-1132. doi:10.1007/s11340-025-01198-7

BibTeX
@article{Carboni2025,
  author = {Carboni, B. and Guruva, S. K. and Gumina, S. and Candela, V. and Tirilló, J. and Sergi, C. and Valente, T. and Lacarbonara, W.},
  title = {Exploring Humerus Bone’s Fracture Patterns and Fixation Systems Via Laser Vibrometry},
  journal = {Experimental Mechanics},
  year = {2025},
  volume = {65},
  number = {7},
  pages = {1117--1132},
  doi = {10.1007/s11340-025-01198-7}
}
Kostenlos starten →