Effects of Drilling Induced Heating During IHD of FRP Laminates
Experimental Mechanics · 2025-09 · 65 (7) · 1069-1080
DOI: 10.1007/s11340-025-01196-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Mechanics, online erschienen am 22.05.2025. Verfasst von M. Horan und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of the Witwatersrand.
Abstract (Originalsprache)
Background
Incremental hole-drilling has been used extensively in composite laminates, however, the low thermal conductivity of GFRP laminates results in drilling induced heat build-up near the hole. This can lead to measurement errors due to post-cure shrinkage of the matrix, and additional thermal drift errors arising from the necessary data acquisition delay after each drilling increment to allow adequate heat dissipation before taking strain measurements.
Objective
Investigate the significance of drilling induced post-cure shrinkage and the effects of different bottom-surface thermal boundary conditions on the drilling induced heat dissipation in GFRP laminates during IHD.
Methods
IHD is performed on GFRP laminates, specifically an annealed $$[0_{8}]$$ [ 0 8 ] laminate and a $$[0_{2}/90_{2}]_{s}$$ [ 0 2 / 90 2 ] s laminate with different support configurations. The through-thickness residual stress distribution is determined using the integral computational method. The magnitude of drilling induced post-cure shrinkage effects and those of the different thermal boundary conditions are investigated.
Results
IHD on the annealed $$[0_{8}]$$ [ 0 8 ] specimens demonstrated that drilling induced post-cure shrinkage effects are not significant. The use of different thermal boundary conditions for the $$[0_{2}/90_{2}]_{s}$$ [ 0 2 / 90 2 ] s specimens demonstrated the necessity for good heat transfer out of the laminate to achieve accurate results.
Conclusions
Carefully performed IHD does not cause sufficient drilling induced heating to result in post-cure shrinkage of GFRP laminates. Experimental parameters and the thermal boundary conditions of the bottom surface must be carefully considered to ensure a successful measurement. A lack of good heat transfer out of the bottom surface of the specimen increases the required testing time and can produce unreliable results.
Förderung
- University of the Witwatersrand
Zitieren
APA
Horan, M., Smit, T. C., & Reid, R. (2025). Effects of Drilling Induced Heating During IHD of FRP Laminates. Experimental Mechanics, 65(7), 1069-1080. https://doi.org/10.1007/s11340-025-01196-9
Vancouver
Horan M, Smit TC, Reid R. Effects of Drilling Induced Heating During IHD of FRP Laminates. Experimental Mechanics. 2025;65(7):1069-1080. doi:10.1007/s11340-025-01196-9
BibTeX
@article{Horan2025,
author = {Horan, M. and Smit, T. C. and Reid, R.G.},
title = {Effects of Drilling Induced Heating During IHD of FRP Laminates},
journal = {Experimental Mechanics},
year = {2025},
volume = {65},
number = {7},
pages = {1069--1080},
doi = {10.1007/s11340-025-01196-9}
}
EUVIMED