EUVIMEDEUVIMED entdecken
ValidierungsstudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

Comparative validation of standard screening tools and an exploratory model for detecting obstructive sleep apnea in hypertrophic cardiomyopathy

Shahid Karim, Balambika S Iyyappan, Sair Tabraiz, Aishwarya Rajendran, Anwar Chahal, Jeffrey B Geske, Alanna M Chamberlain, Virend K Somers

Sleep and Breathing · 2026-12 · 30 (6)

DOI: 10.1007/s11325-026-03844-3 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Sleep and Breathing, online erschienen am 07.11.2026. Verfasst von Shahid Karim und 7 weiteren Autor:innen. Beteiligte Einrichtung: Mayo Clinic, St. Mary's Hospital, 200 1st St NW, Rochester, MN, USA. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Cardiomyopathy, Hypertrophic, Mass Screening. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: American Heart Association, NHLBI NIH HHS, NCATS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STUDY OBJECTIVES: Despite representing a highly prevalent comorbidity, standard screening tools for obstructive sleep apnea (OSA) lack validation in the hypertrophic cardiomyopathy (HCM) population. We sought to prospectively evaluate the diagnostic accuracy of three widely used screening tools against gold-standard polysomnography in an HCM cohort and to explore the potential for a tailored predictive model. METHODS: In this prospective cohort study, patients with HCM completed the Epworth Sleepiness Scale (ESS), Berlin (BQ) and STOP-Bang questionnaires before undergoing inpatient overnight polysomnography. RESULTS: Of 159 participants (median age 60; 64% male), 90 (57%) had OSA (46% mild, 26% moderate, 28% severe). Standard tools yielded modest performance: STOP-Bang [AUC 0.59 (0.50-0.68), sensitivity 77% (68-86), specificity 40% (28-52)]; ESS [AUC 0.58 (0.49-0.67), sensitivity 24% (15-33), specificity 92% (86-98)]; and Berlin [AUC 0.62 (0.53-0.71), sensitivity 65% (55-75), specificity 57% (45-69)]. In contrast, an exploratory model incorporating age, BMI, and waist-hip ratio showed promising preliminary results [AUC 0.82 (0.74-0.88), sensitivity 60% (48-72), specificity 84% (75-91)]. CONCLUSIONS: This study underscores the high prevalence of OSA in patients with HCM and demonstrates that standard screening tools developed for the general population perform poorly in this cohort, complicating clinical triage when polysomnography is delayed. While the derived exploratory model may represent an improvement in risk stratification, these findings require extensive external validation. Targeted screening strategies tailored to the unique pathophysiology of HCM remain necessary to improve OSA identification and management in this high-risk population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea, ObstructiveCardiomyopathy, HypertrophicMass ScreeningHumansFemaleMiddle AgedPolysomnographyMaleProspective StudiesSurveys and QuestionnairesAgedSensitivity and SpecificityReproducibility of ResultsCohort Studies

Stichwörter der Autor:innen

Berlin QuestionnaireEpworth Sleepiness ScaleHCMHypertrophic CardiomyopathyOSAObstructive Sleep ApneaSTOP-Bang QuestionnaireScreening toolspredictive model

Autor:innen und Institutionen

  • Mayo Clinic, St. Mary's Hospital, 200 1st St NW, Rochester, MN, USA.
  • Barts Biomedical Centre, William Harvey Research Institute, Queen Mary University, London, UK.
  • Akron General, Cleveland Clinic, Cleveland, United States.
  • University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN, USA.
  • Mayo Clinic, St. Mary's Hospital, 200 1st St NW, Rochester, MN, USA. Somers.Virend@mayo.edu.

Förderung

  • American Heart Association
  • NHLBI NIH HHS
  • NCATS NIH HHS
  • Sleep Number Corporation
  • Tsai Foundation
  • National Center for Advancing Translational Sciences
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Karim, S., Iyyappan, B. S., Tabraiz, S., Rajendran, A., Chahal, A., Geske, J. B., Chamberlain, A. M., & Somers, V. K. (2026). Comparative validation of standard screening tools and an exploratory model for detecting obstructive sleep apnea in hypertrophic cardiomyopathy. Sleep and Breathing, 30(6). https://doi.org/10.1007/s11325-026-03844-3

Vancouver

Karim S, Iyyappan BS, Tabraiz S, Rajendran A, Chahal A, Geske JB, et al. Comparative validation of standard screening tools and an exploratory model for detecting obstructive sleep apnea in hypertrophic cardiomyopathy. Sleep and Breathing. 2026;30(6). doi:10.1007/s11325-026-03844-3

BibTeX
@article{Karim2026,
  author = {Karim, Shahid and Iyyappan, Balambika S and Tabraiz, Sair and Rajendran, Aishwarya and Chahal, Anwar and Geske, Jeffrey B and Chamberlain, Alanna M and Somers, Virend K},
  title = {Comparative validation of standard screening tools and an exploratory model for detecting obstructive sleep apnea in hypertrophic cardiomyopathy},
  journal = {Sleep and Breathing},
  year = {2026},
  volume = {30},
  number = {6},
  doi = {10.1007/s11325-026-03844-3}
}
Kostenlos starten →