Diagnostic value of wearable and contactless technologies for detecting obstructive sleep apnea: a systematic review and meta-analysis
Sleep and Breathing · 2025-12 · 29 (6)
DOI: 10.1007/s11325-025-03544-4 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Sleep and Breathing, online erschienen am 27.11.2025. Verfasst von Muhammad Hasanain und 12 weiteren Autor:innen. Beteiligte Einrichtung: Dow Medical College, Karachi, Pakistan. muhammad.hasanain.mh@gmail.com. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Wearable Electronic Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Obstructive sleep apnea (OSA) is a common sleep-related breathing disorder, affecting an estimated 1 billion adults worldwide. This study evaluates the diagnostic accuracy of wearable and contactless sleep technologies as alternatives to Polysomnography (PSG) for the detection of OSA. METHODS: A comprehensive search was conducted from inception to September 2025 on PubMed, Cochrane Library, ClinicalTrials.gov, and ScienceDirect. Studies including adults diagnosed with OSA using PSG or HSAT and evaluated with wearable or contactless devices were included. Studies assessing the diagnostic performance of these consumer devices and reporting diagnostic accuracy measures were included. QUADAS-2 was used to assess the risk of bias, and meta-analysis was performed. RESULTS: A total of 59 studies were included, with 3,768 participants in the contactless group and 2,743 participants in the wearable group. For AHI > 15, contactless devices demonstrated a pooled sensitivity of 0.88 (95% CI: 0.86-0.90) and specificity of 0.87 (95% CI: 0.82-0.91), with an AUC of 0.92 (95% CI: 0.89-0.94). Wearable devices showed a pooled sensitivity of 0.87 (95% CI: 0.81-0.92), specificity of 0.86 (95% CI: 0.78-0.91), and an AUC of 0.93 (95% CI: 0.90-0.95). CONCLUSION: Wearable and contactless sleep technologies demonstrate strong diagnostic accuracy. Their role is likely going to be to screen, and compliment PSG rather than replacing it, and providing utility in settings where access to traditional sleep testing is limited. More validation studies across populations, care settings, and comorbidities are needed to make clinical guidelines.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dow Medical College, Karachi, Pakistan. muhammad.hasanain.mh@gmail.com.
- Dow Medical College, Karachi, Pakistan.
- SUNY Upstate Medical University, Syracuse, NY, USA.
- Rawal Institute of Health Sciences, Islamabad, Pakistan.
- Dow International Medical College, Karachi, Pakistan.
- Jinnah Sindh Medical University, Karachi, Pakistan.
ORCID-Profile: Muhammad Hasanain
Zitieren
APA
Hasanain, M., Akram, A., Kabir, A., Javed, H., Usman, M., Jaffar, H., Khan, A. A., Ali Malik, G. M., Tabassum, M., Faizan, M., Anjum, M. U., Umer, M., & Surani, S. (2025). Diagnostic value of wearable and contactless technologies for detecting obstructive sleep apnea: a systematic review and meta-analysis. Sleep and Breathing, 29(6). https://doi.org/10.1007/s11325-025-03544-4
Vancouver
Hasanain M, Akram A, Kabir A, Javed H, Usman M, Jaffar H, et al. Diagnostic value of wearable and contactless technologies for detecting obstructive sleep apnea: a systematic review and meta-analysis. Sleep and Breathing. 2025;29(6). doi:10.1007/s11325-025-03544-4
BibTeX
@article{Hasanain2025,
author = {Hasanain, Muhammad and Akram, Abdullah and Kabir, Aqsa and Javed, Hadiya and Usman, Muhammad and Jaffar, Huda and Khan, Abdullah Aslam and Ali Malik, Ghulam Mustafa and Tabassum, Muzainah and Faizan, Muhammad and Anjum, Muhammad Umair and Umer, Muhammed and Surani, Salim},
title = {Diagnostic value of wearable and contactless technologies for detecting obstructive sleep apnea: a systematic review and meta-analysis},
journal = {Sleep and Breathing},
year = {2025},
volume = {29},
number = {6},
doi = {10.1007/s11325-025-03544-4}
}
EUVIMED