EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Moderately strong intraclass correlations between actigraphic and polysomnographic total sleep time and sleep efficiency in older adults with sleep disturbance

Matthew M Rahimi iD, Craig L Phillips, Nathaniel S Marshall, Rick Wassing, Teha Pun, Ron R Grunstein, Christopher J Gordon

Sleep and Breathing · 2025

DOI: 10.1007/s11325-025-03326-y ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Sleep and Breathing, 2025. Verfasst von Matthew M Rahimi und 6 weiteren Autor:innen. Beteiligte Einrichtung: CIRUS Centre for Sleep and Chronobiology, Woolcock Institute of Medical Research, Macquarie University, Sydney, NSW, Australia. Matthew.Rahimi@mq.edu…. Hauptthemen laut MEDLINE: Actigraphy, Polysomnography, Sleep Wake Disorders. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Macquarie University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the reliability of the GeneActiv actigraphy device in measuring sleep parameters and compare its performance with polysomnography (PSG) in older adults with self-reported sleep disturbances.

Methods

This sub-study was part of a pilot double-blinded randomized controlled crossover trial (CleverLights Study, ANZCTR ID 12619000138189).

Participants

( n = 12, mean age 67.7 years) underwent two nights of sleep studies with simultaneous GeneActiv actigraphy and PSG, separated by a 2-week interval. Sleep parameters including time in bed (TIB), total sleep time (TST), wake after sleep onset (WASO), sleep onset latency (SOL), sleep efficiency (SE), and number of awakenings were assessed. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were used to determine reliability and agreement between methods.

Results

GeneActiv actigraphy demonstrated strong correlations with PSG for TST (ICC = 0.79, p = 0.001) and SE (ICC = 0.85, p < 0.001), but tended to overestimate these parameters. Actigraphy also significantly underestimated the number of awakenings (ICC = 0.45, p = 0.021). Correlations with observed TIB (ICC = 0.30, p = 0.433), WASO (ICC = 0.33, p = 0.386), and SOL (ICC = 0.32, p = 0.056) were non-significant. Bland-Altman plots revealed proportional bias, especially in SOL and the number of awakenings.

Conclusion

Compared to PSG, the GeneActiv actigraphy device provides reliable measurements for total sleep time and sleep efficiency, but agreement was weaker for wake after sleep onset, sleep onset latency, and the number of awakenings. The device showed consistent performance across multiple nights, suggesting good reproducibility. However, it systematically overestimated total sleep time and underestimates wake-related parameters, hence it may not fully replace PSG for detailed sleep assessments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ActigraphyPolysomnographySleep Wake DisordersHumansAgedMaleFemaleReproducibility of ResultsDouble-Blind MethodCross-Over StudiesPilot ProjectsMiddle AgedSleep Duration

Stichwörter der Autor:innen

ActigraphyGeneActivOlder peoplePolysomnographyRepeated measuresSleep

Autor:innen und Institutionen

  • CIRUS Centre for Sleep and Chronobiology, Woolcock Institute of Medical Research, Macquarie University, Sydney, NSW, Australia. Matthew.Rahimi@mq.edu.au.
  • Department of Health Sciences, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia. Matthew.Rahimi@mq.edu.au.
  • CIRUS Centre for Sleep and Chronobiology, Woolcock Institute of Medical Research, Macquarie University, Sydney, NSW, Australia.
  • Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia.
  • Department of Health Sciences, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia.
  • School of Psychological Sciences, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia.

ORCID-Profile: Matthew M Rahimi

Förderung

  • Macquarie University

Zitieren

APA

Rahimi, M. M., Phillips, C. L., Marshall, N. S., Wassing, R., Pun, T., Grunstein, R. R., & Gordon, C. J. (2025). Moderately strong intraclass correlations between actigraphic and polysomnographic total sleep time and sleep efficiency in older adults with sleep disturbance. Sleep and Breathing. https://doi.org/10.1007/s11325-025-03326-y

Vancouver

Rahimi MM, Phillips CL, Marshall NS, Wassing R, Pun T, Grunstein RR, et al. Moderately strong intraclass correlations between actigraphic and polysomnographic total sleep time and sleep efficiency in older adults with sleep disturbance. Sleep and Breathing. 2025. doi:10.1007/s11325-025-03326-y

BibTeX
@article{Rahimi2025,
  author = {Rahimi, Matthew M and Phillips, Craig L and Marshall, Nathaniel S and Wassing, Rick and Pun, Teha and Grunstein, Ron R and Gordon, Christopher J},
  title = {Moderately strong intraclass correlations between actigraphic and polysomnographic total sleep time and sleep efficiency in older adults with sleep disturbance},
  journal = {Sleep and Breathing},
  year = {2025},
  doi = {10.1007/s11325-025-03326-y}
}
Kostenlos starten →