EUVIMEDEUVIMED entdecken
Crossref

Yield of overnight pulse oximetry in screening commercial drivers for obstructive sleep apnea

Alessandro Adami iD, Davide Tonon, Antonio Corica, Deborah Trevisan, Vincent Thijs, Gianluca Rossato

Sleep and Breathing · 2023

DOI: 10.1007/s11325-023-02814-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sleep and Breathing, 2023. Verfasst von Alessandro Adami und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sleep Center, Neurology Dept, IRCCS Sacro Cuore Don Calabria, Via Sempreboni 6, 37024, Negrar, Verona, Italy. alessandro.adami@sacrocuore.it. Hauptthemen laut MEDLINE: Oximetry, Sleep Apnea, Obstructive. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To assess the efficacy of overnight pulse oximetry in screening male commercial drivers (CDs) for obstructive sleep apnea (OSA). METHODS: Consecutive male CDs undergoing their annual scheduled occupational health visit were enrolled from ten transportation facilities. All subjects underwent a home sleep apnea test (HSAT) to determine the Respiratory Event Index (REI). Oxygen desaturation indices (ODIs) below the 3% and 4% thresholds were computed using the built-in HSAT pulse oximeter. We then assessed the association between ODI values and the presence of OSA (defined as an REI ≥ 5 events/hour) as well as moderate to severe OSA (REI ≥ 15 events/hour). RESULTS: Of 331 CDs recruited, 278 (84%) completed the study protocol and 53 subjects were excluded due to inadequate HSAT quality. The included and excluded subjects were comparable in demographics and clinical characteristics. The included CDs had a median age of 49 years (interquartile range (IQR) = 15 years) and a median body mass index of 27 kg/m2 (IQR = 5 kg/m2). One hundred ninety-nine (72%) CDs had OSA, of which 48 (17%) were with moderate OSA and 45 (16%) with severe OSA. The ODI3 and ODI4 receiving operating characteristic curve value were 0.95 for predicting OSA and 0.98-0.96 for predicting moderate to severe OSA. CONCLUSION: Overnight oxygen oximetry may be an effective means to screen CDs for OSA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OximetrySleep Apnea, ObstructiveHumansMaleAdolescentPolysomnographySleepOxygen

Stichwörter der Autor:innen

Commercial driversObstructive sleep apneaOvernight oximetryPolysomnography

Substanzen

Oxygen

Autor:innen und Institutionen

  • Sleep Center, Neurology Dept, IRCCS Sacro Cuore Don Calabria, Via Sempreboni 6, 37024, Negrar, Verona, Italy. alessandro.adami@sacrocuore.it.
  • Sleep Center, Neurology Dept, IRCCS Sacro Cuore Don Calabria, Via Sempreboni 6, 37024, Negrar, Verona, Italy.
  • Florey Institute of Neuroscience and Mental Health, University of Melbourne, Heidelberg, VIC, Australia.

ORCID-Profile: Alessandro Adami

Zitieren

APA

Adami, A., Tonon, D., Corica, A., Trevisan, D., Thijs, V., & Rossato, G. (2023). Yield of overnight pulse oximetry in screening commercial drivers for obstructive sleep apnea. Sleep and Breathing. https://doi.org/10.1007/s11325-023-02814-3

Vancouver

Adami A, Tonon D, Corica A, Trevisan D, Thijs V, Rossato G. Yield of overnight pulse oximetry in screening commercial drivers for obstructive sleep apnea. Sleep and Breathing. 2023. doi:10.1007/s11325-023-02814-3

BibTeX
@article{Adami2023,
  author = {Adami, Alessandro and Tonon, Davide and Corica, Antonio and Trevisan, Deborah and Thijs, Vincent and Rossato, Gianluca},
  title = {Yield of overnight pulse oximetry in screening commercial drivers for obstructive sleep apnea},
  journal = {Sleep and Breathing},
  year = {2023},
  doi = {10.1007/s11325-023-02814-3}
}
Kostenlos starten →