EUVIMEDEUVIMED entdecken
Crossref

Evaluation of radiopacity in preheated fissure sealants: an in-vitro study

Emine Zehra Aydın Çetin, Bilal Özmen, Burcu Yılmaz

Oral Radiology · 2026-07 · 42 (3) · 784-789

DOI: 10.1007/s11282-026-00919-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral Radiology, online erschienen am 29.03.2026. Verfasst von Emine Zehra Aydın Çetin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ondokuz Mayıs University, Faculty of Dentistry, Department of Pediatric Dentistry, Samsun, Turkey. Hauptthemen laut MEDLINE: Pit and Fissure Sealants. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: The use of preheated resin-containing materials is of increasing interest in contemporary dentistry. This study aimed to determine the effect of preheating on the radiopacity values of various fissure sealants. METHODS: In this study, four resin-based fissure sealants were utilised. The materials were divided into two groups, one with and one without preheating, with 18 samples in each group. Each sample was prepared in a cylindrical form (6 × 2 mm) using a Teflon mould. For radiopacity assessment, three radiographs were obtained, each containing 18 samples arranged in sets of six, alongside an eight-step aluminium step-wedge with 0.5-mm increments. The object-focal spot distance, kVp, and mAs values were kept constant while taking radiographs. After obtaining the mean gray values of the samples using ImageJ software, the values were converted to equivalent aluminium thickness using CurveExpert Pro software. One-way analysis of variance (ANOVA), the Tukey multiple comparison test, and the t-test were used for statistical analysis. RESULTS: A significant difference was found between different fissure sealants (p 0.05). CONCLUSIONS: The radiopacity of the fissure sealants varied among manufacturers; however, preheating at 55 °C did not produce any change in radiopacity in any of the materials tested.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pit and Fissure SealantsMaterials TestingIn Vitro TechniquesHumansHot TemperatureContrast Media

Stichwörter der Autor:innen

Fissure sealantPreheatingRadiopacity

Substanzen

Pit and Fissure SealantsContrast Media

Autor:innen und Institutionen

  • Ondokuz Mayıs University, Faculty of Dentistry, Department of Pediatric Dentistry, Samsun, Turkey.
  • Ondokuz Mayıs University, Faculty of Dentistry, Department of Pediatric Dentistry, Samsun, Turkey. bilalozmen@omu.edu.tr.

Zitieren

APA

Aydın Çetin, E. Z., Özmen, B., & Yılmaz, B. (2026). Evaluation of radiopacity in preheated fissure sealants: an in-vitro study. Oral Radiology, 42(3), 784-789. https://doi.org/10.1007/s11282-026-00919-5

Vancouver

Aydın Çetin EZ, Özmen B, Yılmaz B. Evaluation of radiopacity in preheated fissure sealants: an in-vitro study. Oral Radiology. 2026;42(3):784-789. doi:10.1007/s11282-026-00919-5

BibTeX
@article{Aydnetin2026,
  author = {Aydın Çetin, Emine Zehra and Özmen, Bilal and Yılmaz, Burcu},
  title = {Evaluation of radiopacity in preheated fissure sealants: an in-vitro study},
  journal = {Oral Radiology},
  year = {2026},
  volume = {42},
  number = {3},
  pages = {784--789},
  doi = {10.1007/s11282-026-00919-5}
}
Kostenlos starten →