Handheld point-of-care ultrasound for chairside assessment of masseter muscle: a pilot study

Nishant Kharidehal, Jonathan Chu, Ivonne Hernandez, Paul W Major, Reid Friesen, Fabiana T Almeida

Oral Radiology · 2026

DOI: 10.1007/s11282-026-00907-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral Radiology, 2026. Verfasst von Nishant Kharidehal und 5 weiteren Autor:innen. Beteiligte Einrichtung: Mike Petryk School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, 11405 87 Avenue NW, T6G 1C9, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Masseter Muscle, Point-of-Care Systems. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: This study aimed to assess the feasibility of handheld ultrasound for scanning and measuring masseter muscle thickness. METHODS: This prospective pilot study included adult participants aged 18 and older. Inclusion criteria specified healthy individuals without pain or a TMD diagnosis in the last six months and not receiving neuromodulators as a treatment for TMJ-related issues. Exclusion criteria included individuals with developmental disorders affecting the craniofacial skeleton or with connective tissue and dermatological disorders impacting skin thickness. A scanning protocol was developed for a new handheld ultrasound system [4-12 MHz; (Lumify, Philips, USA)] to assess the masseter muscle thickness of participants in relaxed and clenched states. RESULTS: Two evaluators analyzed ninety-two ultrasound scans from 12 participants. Intraclass correlation coefficient and standard deviations between the observers were calculated. Reliability for masseter measurements ranged from good to excellent (ICC 0.84-0.93) for Intra-observer and excellent for Inter-observer (ICC 0.93-0.98). CONCLUSION: The preliminary findings of this study demonstrate the high reliability of handheld ultrasound in assessing masseter muscle. The results support the use of handheld ultrasound to assess masseter muscle thickness. This system can be an alternative to cart-based systems facilitating the implementation of ultrasound as a chair-side tool in dentistry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Masseter MusclePoint-of-Care SystemsHumansPilot ProjectsUltrasonographyFemaleProspective StudiesMaleAdultFeasibility StudiesReproducibility of ResultsMiddle AgedAdolescent

Stichwörter der Autor:innen

Masseter muscleTemporomandibular joint disordersUltrasonography

Autor:innen und Institutionen

  • Mike Petryk School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, 11405 87 Avenue NW, T6G 1C9, Edmonton, Alberta, Canada.
  • Mike Petryk School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, 11405 87 Avenue NW, T6G 1C9, Edmonton, Alberta, Canada. fabiana@ualberta.ca.

Zitieren

APA

Kharidehal, N., Chu, J., Hernandez, I., Major, P. W., Friesen, R., & Almeida, F. T. (2026). Handheld point-of-care ultrasound for chairside assessment of masseter muscle: a pilot study. Oral Radiology. https://doi.org/10.1007/s11282-026-00907-9

Vancouver

Kharidehal N, Chu J, Hernandez I, Major PW, Friesen R, Almeida FT. Handheld point-of-care ultrasound for chairside assessment of masseter muscle: a pilot study. Oral Radiology. 2026. doi:10.1007/s11282-026-00907-9

BibTeX
@article{Kharidehal2026,
  author = {Kharidehal, Nishant and Chu, Jonathan and Hernandez, Ivonne and Major, Paul W and Friesen, Reid and Almeida, Fabiana T},
  title = {Handheld point-of-care ultrasound for chairside assessment of masseter muscle: a pilot study},
  journal = {Oral Radiology},
  year = {2026},
  doi = {10.1007/s11282-026-00907-9}
}
Kostenlos starten →