Upper airway volumetry using CBCT: a critical review of methodological inconsistencies and open-source software applications
Oral Radiology · 2026-07 · 42 (3) · 482-490
DOI: 10.1007/s11282-026-00901-1 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Oral Radiology, online erschienen am 01.04.2026. Verfasst von Pedro Dos Santos Anjo E Aguero und 8 weiteren Autor:innen. Beteiligte Einrichtung: Oral and Maxillofacial Surgery and Traumatology Service, Hospital das Clínicas, Medical School, São Paulo University, São Paulo, Brazil. psa.aguero@g…. Hauptthemen laut MEDLINE: Software, Cone-Beam Computed Tomography. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To critically synthesize methodological heterogeneity in upper airway volumetry based in CBCT and compare open-source versus commercial tools in airway assessment. METHODS: We conducted an integrative review (2010–2025) in PubMed/Scopus, screened 1,427 records, and included 29 studies. We extracted imaging parameters, anatomical limits, segmentation strategies (fixed/adaptive thresholds; manual/semi-automatic/automatic), validation approaches, and reproducibility metrics. RESULTS: Substantial heterogeneity was found in acquisition protocols, head posture control, anatomical boundaries, and thresholding strategies, limiting cross-study comparability. When protocols were standardized, open-source software achieved reliability comparable to commercial packages. CONCLUSIONS: Standardized protocols are essential particularly for HU thresholding, anatomical limits, and validation. Open-source solutions are clinically viable where accessibility and reproducibility are priorities
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Oral and Maxillofacial Surgery and Traumatology Service, Hospital das Clínicas, Medical School, São Paulo University, São Paulo, Brazil. psa.aguero@gmail.com.
- Edificio Estilo Jardins, Rua Arruda Alvim, N° 94, Apto 302, Pinheiros, São Paulo, SP, CEP 05410-020, Brazil. psa.aguero@gmail.com.
- Department of Dentistry, Hospital das Clínicas, Medical School, São Paulo University, São Paulo, Brazil.
- Oral and Maxillofacial Surgery and Traumatology Service, Hospital das Clínicas, Medical School, São Paulo University, São Paulo, Brazil.
- Department of Otorhinolaryngology, Hospital das Clínicas, Medical School, São Paulo University, São Paulo, Brazil.
Zitieren
APA
Dos Santos Anjo E Aguero, P., Barbosa, B. L., de Cássia d'Ottaviano Nápole, R., Antequera, R., Yonezaki, F., Voegels, R. L., de Rezende Pina, F., Machado, G. G., & Zambon, C. E. (2026). Upper airway volumetry using CBCT: a critical review of methodological inconsistencies and open-source software applications. Oral Radiology, 42(3), 482-490. https://doi.org/10.1007/s11282-026-00901-1
Vancouver
Dos Santos Anjo E Aguero P, Barbosa BL, de Cássia d'Ottaviano Nápole R, Antequera R, Yonezaki F, Voegels RL, et al. Upper airway volumetry using CBCT: a critical review of methodological inconsistencies and open-source software applications. Oral Radiology. 2026;42(3):482-490. doi:10.1007/s11282-026-00901-1
BibTeX
@article{DosSantosAnjoEAguero2026,
author = {Dos Santos Anjo E Aguero, Pedro and Barbosa, Beatriz Leal and de Cássia d'Ottaviano Nápole, Rita and Antequera, Reynaldo and Yonezaki, Frederico and Voegels, Richard Louis and de Rezende Pina, Fabio and Machado, Gustavo Groethe and Zambon, Camila Eduarda},
title = {Upper airway volumetry using CBCT: a critical review of methodological inconsistencies and open-source software applications},
journal = {Oral Radiology},
year = {2026},
volume = {42},
number = {3},
pages = {482--490},
doi = {10.1007/s11282-026-00901-1}
}
EUVIMED