Comparison of 30° and 70° arthroscopes in canine hip arthroscopy: a 3D-printed model study
Veterinary Research Communications · 2026
DOI: 10.1007/s11259-026-11481-0 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Research Communications, 2026. Verfasst von Piotr Trębacz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Surgery and Anaesthesiology, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159…. Hauptthemen laut MEDLINE: Arthroscopy, Printing, Three-Dimensional, Hip Joint, Arthroscopes. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Hip arthroscopy is a valuable diagnostic and surgical tool in veterinary medicine; however, the optimal arthroscope viewing angle for the canine coxofemoral joint has not been established. We hypothesised that a 70° arthroscope would provide superior visualisation of the hip joint cavity compared to the standard 30° arthroscope when inserted via a dorso-lateral approach. To test this hypothesis, five 3D-printed canine hip joint models were developed using computed tomography (CT) scans of large-breed dogs. The articular surfaces were embossed with a 1 × 1 mm checkerboard pattern to enable objective quantification of the visible area. Arthroscopy was performed with 2.7-mm-diameter 30° and 70° arthroscopes at four positions (3, 6, 9, and 12 o’clock), and the visible area was calculated by counting visible tiles. Statistical analysis was performed using a mixed-effect general linear model. There was no significant overall difference in the visible area between the two arthroscope viewing angles ( P = 0.977). However, arthroscope position significantly affected the visible area ( P < 0.001), and a significant interaction between viewing angle and position was identified ( P = 0.001). Notably, the visible area produced by the 70° arthroscope was significantly smaller than that produced by the 30° arthroscope at the 12 o’clock position ( P = 0.026). However, at the 3 o’clock position, the visible area produced by the 70° arthroscope appeared to be larger than that produced by the 30° arthroscope. Nevertheless, this difference was not significant ( P = 0.085). The results suggest that, in this experimental model, the 70° arthroscope provided a comparable overall visible area of the artificial hip joint surface to the 30° arthroscope during dorso-lateral canine hip arthroscopy. Further comparative studies, particularly on calibrated cadaveric hip joints, are required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Small Animal Surgery and Anaesthesiology, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159 C, Warsaw, 02-776, Poland. piotr_trebacz@sggw.edu.pl.
- Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Zabrze, Poland.
- CABIOMEDE Ltd, Kielce, Poland.
- Division of Veterinary Epidemiology and Economics, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159 C, Warsaw, 02-776, Poland.
ORCID-Profile: Piotr Trębacz
Zitieren
APA
Trębacz, P., Pawlik, M., Czopowicz, M., Barteczko, A., Kurkowska, A., & Piątek, A. (2026). Comparison of 30° and 70° arthroscopes in canine hip arthroscopy: a 3D-printed model study. Veterinary Research Communications. https://doi.org/10.1007/s11259-026-11481-0
Vancouver
Trębacz P, Pawlik M, Czopowicz M, Barteczko A, Kurkowska A, Piątek A. Comparison of 30° and 70° arthroscopes in canine hip arthroscopy: a 3D-printed model study. Veterinary Research Communications. 2026. doi:10.1007/s11259-026-11481-0
BibTeX
@article{Trbacz2026,
author = {Trębacz, Piotr and Pawlik, Mateusz and Czopowicz, Michał and Barteczko, Anna and Kurkowska, Aleksandra and Piątek, Agata},
title = {Comparison of 30° and 70° arthroscopes in canine hip arthroscopy: a 3D-printed model study},
journal = {Veterinary Research Communications},
year = {2026},
doi = {10.1007/s11259-026-11481-0}
}
EUVIMED