EUVIMEDEUVIMED entdecken
Crossref

Clinical use of the canine foetal kidney formula in dogs of different maternal sizes during the last ten days before parturition

Giulia Siena, Francesca di Nardo, Barbara Contiero, Chiara Milani

Veterinary Research Communications · 2023

DOI: 10.1007/s11259-023-10120-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Research Communications, 2023. Verfasst von Giulia Siena und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy. giulia.siena@phd.unip…. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Parturition. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Data concerning the use of the canine foetal kidney length (L) formula in the prediction of parturition timing are still lacking. In our study, we aimed to evaluate the accuracy of the L formula in predicting the parturition date during the last 10 days of pregnancy. Twenty-five clinically healthy pregnant bitches, aged 2-9 years and weighing 3.5-52.2 kg, were ultrasonographically monitored from -11 to 0 days before parturition (dbp). Kidney L was measured for the three most caudal foetuses, and the parturition day was estimated using the kidney formula, whose accuracy was calculated as the percentage of cases estimated (ranges of ± 1 or ± 2 days) on the actual parturition date. A K-proportions test was performed to identify differences in the accuracy among maternal sizes and the sex ratio of pups, and a two-proportions z-test was performed to identify differences between litter size classes (≤ 7 vs. > 7 pups) and time ranges (-11/-5 and -4/0 dbp). An accuracy of 35% within ± 2 days was found in the range of -11/-5 dbp and an accuracy of 30% within ± 2 days was found in the range of -4/0 dbp. The accuracy differed between small (53% ±1 day and 60% ±2 days) and large (10% within ± 1 and ± 2 days) bitches (P = 0.019 within ± 1 day, and P = 0.007 within ± 2 days). For small litter sizes, the accuracy was 38% within ± 1 day and 44% within ± 2 days, and for large litter sizes, it was 14% within ± 1 and ± 2 days. A threshold value was found between litter size classes within ± 2 days. The use of the L formula during the last ten days of pregnancy did not seem to warrant good accuracy in the prediction of parturition date. Further studies on different maternal sizes should be performed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalParturitionPregnancyFemaleDogsAnimalsLitter Size

Stichwörter der Autor:innen

DogFormulaKidney lengthParturition datePregnancyUltrasound

Autor:innen und Institutionen

  • Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy. giulia.siena@phd.unipd.it.
  • Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy.

Zitieren

APA

Siena, G., di Nardo, F., Contiero, B., & Milani, C. (2023). Clinical use of the canine foetal kidney formula in dogs of different maternal sizes during the last ten days before parturition. Veterinary Research Communications. https://doi.org/10.1007/s11259-023-10120-2

Vancouver

Siena G, di Nardo F, Contiero B, Milani C. Clinical use of the canine foetal kidney formula in dogs of different maternal sizes during the last ten days before parturition. Veterinary Research Communications. 2023. doi:10.1007/s11259-023-10120-2

BibTeX
@article{Siena2023,
  author = {Siena, Giulia and di Nardo, Francesca and Contiero, Barbara and Milani, Chiara},
  title = {Clinical use of the canine foetal kidney formula in dogs of different maternal sizes during the last ten days before parturition},
  journal = {Veterinary Research Communications},
  year = {2023},
  doi = {10.1007/s11259-023-10120-2}
}
Kostenlos starten →