Rapid bedside microscopic leukocyte counting for the diagnosis of peritoneal dialysis–associated peritonitis: diagnostic accuracy compared with automated flow cytometry
International Urology and Nephrology · 2026
DOI: 10.1007/s11255-026-05140-1 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Urology and Nephrology, 2026. Verfasst von Luca Nardelli und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology, Dialysis and Kidney Transplantation, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. lcn.nardelli@gm…. Hauptthemen laut MEDLINE: Peritoneal Dialysis, Flow Cytometry, Peritonitis, Point-of-Care Testing. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Peritoneal dialysis (PD)-related peritonitis remains a major cause of technique failure, morbidity, and mortality. Timely diagnosis is crucial, yet conventional white blood cell (WBC) quantification by flow cytometry (FCC) requires centralized laboratory processing, delaying treatment. This study aimed to validate a direct manual microscopic (DMC) method for bedside quantification of WBCs in peritoneal effluent as a rapid diagnostic alternative. METHODS: In this single-center study, 40 PD patients underwent 250 paired WBC assessments between January 2024 and June 2025. Peritoneal effluent samples were analyzed by both DMC and FCC at peritonitis onset, during treatment follow-up, and in asymptomatic controls. Diagnostic performance was evaluated using Spearman's correlation, receiver operating characteristic analysis, and the Youden index, employing FCC as the reference standard (> 100 cells/μL). RESULTS: Across all evaluations, DMC and FCC showed a strong correlation (ρ = 0.91, p < 0.0001). In patients evaluated for suspected peritonitis (n = 36), DMC achieved a sensitivity of 97.0% and specificity of 100% at a cut-off of 20 cells/20 HPFs (AUC = 0.99; 95% CI 0.98-1.00). During follow-up (n = 187), correlation remained high (ρ = 0.89, p < 0.0001), with sensitivity 97.2% and specificity 83.4% at 12 cells/20 HPFs (AUC = 0.97; 95% CI 0.95-0.99). CONCLUSION: DMC provides a reliable, rapid, and quantitative alternative to automated cytometry for diagnosing and monitoring PD-related peritonitis. Its simplicity, affordability, and bedside applicability make it particularly suitable for integration with home turbidity monitoring systems to improve timely peritonitis management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Nephrology, Dialysis and Kidney Transplantation, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. lcn.nardelli@gmail.com.
- Department of Clinical Sciences and Community Health, Università degli studi di Milano, Milan, Italy. lcn.nardelli@gmail.com.
- Division of Nephrology, Dialysis and Kidney Transplantation, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
- Department of Clinical Sciences and Community Health, Università degli studi di Milano, Milan, Italy.
- Nephrology Unit, ASST Spedali Civili di Brescia, Brescia, Italy.
- Department of Medical and Surgical Specialities, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.
Zitieren
APA
Nardelli, L., Scalamogna, A., Garigali, G., Sikharulidze, A., Abinti, M., Hida, A., Moscardino, S., Alberici, F., & Castellano, G. (2026). Rapid bedside microscopic leukocyte counting for the diagnosis of peritoneal dialysis–associated peritonitis: diagnostic accuracy compared with automated flow cytometry. International Urology and Nephrology. https://doi.org/10.1007/s11255-026-05140-1
Vancouver
Nardelli L, Scalamogna A, Garigali G, Sikharulidze A, Abinti M, Hida A, et al. Rapid bedside microscopic leukocyte counting for the diagnosis of peritoneal dialysis–associated peritonitis: diagnostic accuracy compared with automated flow cytometry. International Urology and Nephrology. 2026. doi:10.1007/s11255-026-05140-1
BibTeX
@article{Nardelli2026,
author = {Nardelli, Luca and Scalamogna, Antonio and Garigali, Giuseppe and Sikharulidze, Anna and Abinti, Matteo and Hida, Anxhela and Moscardino, Sara and Alberici, Federico and Castellano, Giuseppe},
title = {Rapid bedside microscopic leukocyte counting for the diagnosis of peritoneal dialysis–associated peritonitis: diagnostic accuracy compared with automated flow cytometry},
journal = {International Urology and Nephrology},
year = {2026},
doi = {10.1007/s11255-026-05140-1}
}
EUVIMED