Is the direct in-scope suction (DISS) the solution for the non-prestenting and sheathless flexible ureteroscopy?
International Urology and Nephrology · 09.01.2026 · 58 (7) · 2537-2543
DOI: 10.1007/s11255-026-05007-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Urology and Nephrology, online erschienen am 09.01.2026. Verfasst von Luis Rico und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Hospital Aleman, Buenos Aires, Argentina. luisrico_01@hotmail.com. Hauptthemen laut MEDLINE: Ureteroscopy, Kidney Calculi, Ureteroscopes, Lithotripsy, Laser. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The concept of suction has revolutionized the modern endourology. Direct in-scope suction (DISS) allows for simultaneous or alternating suction and aspiration during the endoscopic laser lithotripsy, using the scope as a conduit to aspirate fine dust or fragments from all the renal calyxes. This study aimed to evaluate the feasibility, safety, and effectiveness of DISS in non-prestented and sheathless flexible ureteroscopy. MATERIALS AND METHODS: A retrospective study was conducted of consecutive patients undergoing DISS at the Hospital Aleman of Buenos Aires between March 2025 and September 2025. We included patients with non-complex kidney stones and those in whom a suction ureteral access sheath was not used and who did not have a ureteral stent before the procedure. A 7.5Fr disposable flexible scope (PU3033AH) was used. Stone-free rate (SFR) was defined according to a 4-week postoperative low-dose non-contrast computed tomography scan as Grade A = absence of stone fragments, Grade B = stone fragments 2 mm. Postoperative complications were evaluated according to the Clavien-Dindo classification. RESULTS: In all, 81 patients were included. The mean stone volume was 582 mm3 (353-858). Thulium Fiber Laser was used in 79.0% and Magneto-Ho:YAG pulse modality in the remaining 21.0%. Total operative time was 40 min (35-45 min) and a postoperative double-J stent was placed in 84.3%. The Grade A SFR was 86.4% and Grade B 13.6% with no patients in Grade C definition. The overall postoperative complications rate (Clavien-Dindo ≤ 2) was 8.6% with no major complications. CONCLUSION: DISS without the use of a ureteral access sheath and no preoperative double-J stent placement is effective and safe in selected patients. Further clinical trials are needed to reaffirm the results obtained in this initial experience.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Hospital Aleman, Buenos Aires, Argentina. luisrico_01@hotmail.com.
- Department of Urology, Hospital Aleman, Buenos Aires, Argentina.
Zitieren
APA
Rico, L., Ramos, L. B., Jaramillo, J. Á., Blas, L., & Contreras, P. (2026). Is the direct in-scope suction (DISS) the solution for the non-prestenting and sheathless flexible ureteroscopy?. International Urology and Nephrology, 58(7), 2537-2543. https://doi.org/10.1007/s11255-026-05007-5
Vancouver
Rico L, Ramos LB, Jaramillo JÁ, Blas L, Contreras P. Is the direct in-scope suction (DISS) the solution for the non-prestenting and sheathless flexible ureteroscopy?. International Urology and Nephrology. 2026;58(7):2537-2543. doi:10.1007/s11255-026-05007-5
BibTeX
@article{Rico2026,
author = {Rico, Luis and Ramos, Lorena Banda and Jaramillo, Juliana Álvarez and Blas, Leandro and Contreras, Pablo},
title = {Is the direct in-scope suction (DISS) the solution for the non-prestenting and sheathless flexible ureteroscopy?},
journal = {International Urology and Nephrology},