Aspiration properties of flexible and navigable suction ureteral access sheath (FANS) and flexible ureteroscope with direct-in-scope suction (DISS): an in-vitro experimental study by EAU young academic urologists (YAU) urolithiasis and endourology working group
International Urology and Nephrology · 10.02.2025 · 57 (8) · 2371-2377
DOI: 10.1007/s11255-025-04405-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Urology and Nephrology, online erschienen am 10.02.2025. Verfasst von Arman Tsaturyan und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department Or Urology, Yerevan State Medical University After Mkhitar Heratsi, Yerevan, Armenia. tsaturyanarman@yahoo.com. Hauptthemen laut MEDLINE: Ureteroscopes, Ureteroscopy, Ureteral Calculi. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To illustratively evaluate and compare the effectiveness of aspiration of 7.5Fr and 9.2Fr single-use flexible ureteroscopes with direct in-scope-suction (DISS) with a 12/14Fr flexible and navigable suction ureteral access sheath (FANS) in an in-vitro setting. METHODS: Our experimental setup included a 6.5-size sterile glove, 2 mm and 4 mm stone fragments, and a porcine ureter. Three experimental scenarios were evaluated in the upper, middle and lower calyx: 1. Suction via 12/14Fr FANS, 2. Suction via 7.5Fr DISS, 3. Suction via 9.2Fr DISS. RESULTS: Evacuation of the 2 mm stone was reported in all trials regardless of the used instrument. Aspiration and repositioning of the 4 mm fragment was observed from the upper calyx with all instruments. In the middle calyx, stone evacuation was successful in 5 out of 5 trials with 7.5Fr DISS, and 3 out of 5 with 12/14Fr FANS or 9.2Fr DISS. Stone relocation using suction with subsequent evacuation of the 4 mm fragment from the lower calyx was achieved in none of the trials with 12/14Fr FANS and only in 1 trial with 9.2Fr DISS scope whereas it was successful in 4 trials when 7.5Fr DISS was used. Collapse of the pelvicalyceal system (PCS) was more pronounced with the 12/14Fr FANS and 9.2Fr DISS scope (3-4 s) compared to 7.5Fr DISS scope (6-7 s). CONCLUSION: In this study, the 7.5Fr single-use flexible ureteroscope was found to be superior in terms of stone extraction and relocation, while it seemed to have less impact on the collapse of the PCS compared to 9.2Fr DISS and 12/14Fr FANS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department Or Urology, Yerevan State Medical University After Mkhitar Heratsi, Yerevan, Armenia. tsaturyanarman@yahoo.com.
- Department of Urology, Erebouni Medical Center, 0087, Yerevan, Armenia. tsaturyanarman@yahoo.com.
- EAU Young Academic Urologists (YAU) Urolithiasis and Endourology Working Group Arnhem, NL-6803, Arnhem, The Netherlands. tsaturyanarman@yahoo.com.
- Advancing Suction and Pressure and Innovative Research in Endourology (ASPIRE), Yerevan, Armenia. tsaturyanarman@yahoo.com.
- Department of Urology, University of Patras, Patras, Greece.
- EAU Young Academic Urologists (YAU) Urolithiasis and Endourology Working Group Arnhem, NL-6803, Arnhem, The Netherlands.
Zitieren
APA
Tsaturyan, A., Peteinaris, A., Ventimiglia, E., Sargsyan, H., Muradyan, A., Sener, T. E., Keller, E. X., De Coninck, V., Esperto, F., Mykoniatis, G., Juliebø-Jones, P., Tzelves, L., Del Rio, A. S., Yuen, S. K. K., Gauhar, V., Traxer, O., Liatsikos, E., Kallidonis, P., Somani, B., & Pietropaolo, A. (2025). Aspiration properties of flexible and navigable suction ureteral access sheath (FANS) and flexible ureteroscope with direct-in-scope suction (DISS): an in-vitro experimental study by EAU young academic urologists (YAU) urolithiasis and endourology working group. International Urology and Nephrology, 57(8), 2371-2377. https://doi.org/10.1007/s11255-025-04405-5
Vancouver
Tsaturyan A, Peteinaris A, Ventimiglia E, Sargsyan H, Muradyan A, Sener TE, et al. Aspiration properties of flexible and navigable suction ureteral access sheath (FANS) and flexible ureteroscope with direct-in-scope suction (DISS): an in-vitro experimental study by EAU young academic urologists (YAU) urolithiasis and endourology working group. International Urology and Nephrology. 2025;57(8):2371-2377. doi:10.1007/s11255-025-04405-5
BibTeX
@article{Tsaturyan2025,
author = {Tsaturyan, Arman and Peteinaris, Angelis and Ventimiglia, Eugenio and Sargsyan, Hakob and Muradyan, Armen and Sener, Tarik Emre and Keller, Etienne X and De Coninck, Vincent and Esperto, Francesco and Mykoniatis, Giannis and Juliebø-Jones, Patrick and Tzelves, Lazaros and Del Rio, Alba Sierra and Yuen, Steffi Kar Kei and Gauhar, Vineet and Traxer, Olivier and Liatsikos, Evangelos and Kallidonis, Panagiotis and Somani, Bhaskar and Pietropaolo, Amelia},
title = {Aspiration properties of flexible and navigable suction ureteral access sheath (FANS) and flexible ureteroscope with direct-in-scope suction (DISS): an in-vitro experimental study by EAU young academic urologists (YAU) urolithiasis and endourology working group},
journal = {International Urology and Nephrology},
year = {2025},
volume = {57},
number = {8},
pages = {2371--2377},
doi = {10.1007/s11255-025-04405-5}
}
EUVIMED