EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer

Aykut Fatih Güven, Onur Özdal Mengi, Salah Kamel, Anas Bouaouda, Fatma A. Hashim

The Journal of Supercomputing · 07.03.2026 · 82 (4)

DOI: 10.1007/s11227-026-08348-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Supercomputing, online erschienen am 07.03.2026. Verfasst von Aykut Fatih Güven und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, Yalova University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ensuring frequency stability in interconnected power systems is challenging due to continuous load variations and fluctuations in tie-line power. This study focuses on designing and optimizing controllers for Automatic Generation Control (AGC) of a two-area power system to achieve zero-frequency deviation under dynamic load conditions. Five different controllers—PID (Proportional-Integral-Derivative), PIDn, FOPID (Fractional Order PID), TID (Tilt-Integral-Derivative), and PIDA—were tested. Their parameters were optimized using seven advanced metaheuristic algorithms: Artificial Rabbit Optimization, Chernobyl Disaster Optimizer (CDO), Modified Chernobyl Disaster Optimizer (mCDO), Golden Jackal Optimization, Honey Badger Algorithm, Mont-Flame Optimization, and Spider Wasp Optimizer. A total of 35 simulation studies were conducted, and performance was evaluated using the Integral of Time-Weighted Absolute Error (ITAE) metric Among the tested controllers, the FOPID-mCDO combination achieved the lowest ITAE value (0.320684), a settling time of 3.6 s, and minimal overshoot (0.0083 Hz) and undershoot (− 0.1480 Hz). Compared to conventional PID controllers, this configuration reduced settling time by 10% and improved frequency stability under dynamic load variations. The proposed mCDO algorithm, which integrates neighborhood–global and wandering search strategies to enhance the exploration–exploitation balance of the original CDO, outperformed the standard CDO by enabling faster convergence and more precise parameter tuning. The findings indicate that the FOPID-mCDO combination is a promising approach for automatic generation control in multi-area power systems.

Förderung

  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
  • Yalova University

Zitieren

APA

Güven, A. F., Mengi, O. Ö., Kamel, S., Bouaouda, A., & Hashim, F. A. (2026). Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer. The Journal of Supercomputing, 82(4). https://doi.org/10.1007/s11227-026-08348-1

Vancouver

Güven AF, Mengi OÖ, Kamel S, Bouaouda A, Hashim FA. Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer. The Journal of Supercomputing. 2026;82(4). doi:10.1007/s11227-026-08348-1

BibTeX
@article{Gven2026,
  author = {Güven, Aykut Fatih and Mengi, Onur Özdal and Kamel, Salah and Bouaouda, Anas and Hashim, Fatma A.},
  title = {Enhanced FOPID controller for AGC of two-area power system using a Modified Chernobyl Disaster Optimizer},
  journal = {The Journal of Supercomputing},
  year = {2026},
  volume = {82},
  number = {4},
  doi = {10.1007/s11227-026-08348-1}
}
Kostenlos starten →