EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Filter-Free Two-Stage Reconstruction for Low-Dose CT Across Regular and Irregular Sparse-Angle Sampling

Tim Selig, Patrick Bauer, Thomas März, Martin Storath, Jürgen Frikel, Andreas Weinmann

Sensing and Imaging · 08.08.2026 · 27 (1)

DOI: 10.1007/s11220-026-00834-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensing and Imaging, online erschienen am 08.08.2026. Verfasst von Tim Selig und 5 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hochschule Darmstadt University of Applied Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low-dose and sparse-angle computed tomography (CT) reduces radiation exposure but makes image reconstruction challenging due to noisy and limited projection data. Popular reconstruction methods are based on two-stage approaches, typically involving filtered backprojection (FBP) followed by a neural network to enhance the image. FBP, however, amplifies noise and struggles with irregular sampling. Therefore, we explore filter-free initial reconstructions, shifting the filtering step to the neural network. In particular, we investigate how two-stage methods can be adapted for cases where implementing explicit filters is difficult, such as with irregular sampling. Specifically, we propose backprojection (BP) or a small number of Landweber iterations as the initial reconstruction, followed by a fine-tuned DRUNet model, referred to as BP-DRUNet and Landweber-DRUNet, respectively. For evaluation, we consider both regular and irregular sampling conditions: For regular sampling, we compare BP-DRUNet with FBP-DRUNet (using FBP as the initial stage) in order to benchmark against standard two-stage approaches. BP-DRUNet performs comparably to FBP-DRUNet under regular sampling. In irregular sampling, Landweber-DRUNet improves reconstruction quality with more iterations, though at the cost of longer training and inference times. Experiments are carried out on synthetic and real CT datasets with parallel- and fan-beam acquisitions across different sparse-angle setups.

Förderung

  • Hochschule Darmstadt University of Applied Sciences

Zitieren

APA

Selig, T., Bauer, P., März, T., Storath, M., Frikel, J., & Weinmann, A. (2026). Filter-Free Two-Stage Reconstruction for Low-Dose CT Across Regular and Irregular Sparse-Angle Sampling. Sensing and Imaging, 27(1). https://doi.org/10.1007/s11220-026-00834-3

Vancouver

Selig T, Bauer P, März T, Storath M, Frikel J, Weinmann A. Filter-Free Two-Stage Reconstruction for Low-Dose CT Across Regular and Irregular Sparse-Angle Sampling. Sensing and Imaging. 2026;27(1). doi:10.1007/s11220-026-00834-3

BibTeX
@article{Selig2026,
  author = {Selig, Tim and Bauer, Patrick and März, Thomas and Storath, Martin and Frikel, Jürgen and Weinmann, Andreas},
  title = {Filter-Free Two-Stage Reconstruction for Low-Dose CT Across Regular and Irregular Sparse-Angle Sampling},
  journal = {Sensing and Imaging},
  year = {2026},
  volume = {27},
  number = {1},
  doi = {10.1007/s11220-026-00834-3}
}
Kostenlos starten →