Comparing a Fixed and Freely Rotating Capsule in a Dry Powder Inhaler Under Realistic Breathing Conditions
Pharmaceutical Research · 2026-10 · 43 (10) · 3849-3862
DOI: 10.1007/s11095-026-04184-3 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Pharmaceutical Research, online erschienen am 31.08.2026. Verfasst von Karan Shrivastava und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, 600036, India. Hauptthemen laut MEDLINE: Dry Powder Inhalers. Die Arbeit nennt 22 Literaturangaben. Gefördert von: ANRF.
Abstract (Originalsprache)
PURPOSE: To investigate the performance of a capsule-based dry powder inhaler (DPI) under two device configurations - free-axis and fixed-axis capsule rotation - across steady-state and transient inhalation profiles. METHOD: Two new research-based transparent capsule-based DPI were developed-one with a fixed capsule rotational axis and another with a floating capsule configuration. High-speed imaging was used to capture capsule motion, and the effects of flow regimes (laminar, transient, and turbulent), capsule rotation, and breathing profiles on capsule RPM, wall collisions, and powder retention were analyzed. CONCLUSIONS: Fixed-axis rotation significantly outperformed free-axis rotation (~ 6 × higher RPM and lower powder retention). Higher flow rates and faster-accelerating transient profiles increased RPM and collision frequency, enhancing drug release. Fixing the rotational axis of the capsule had the greatest benefit for the slow inhalation profile. The findings offer key insights for the design of future capsule-based DPIs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, 600036, India.
- School of Mechanical and Materials Engineering, IIT Mandi, Mandi, HP, 175075, India.
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW, 2006, Australia.
- School of Mechanical and Materials Engineering, IIT Mandi, Mandi, HP, 175075, India. gajendra@iitmandi.ac.in.
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW, 2006, Australia. gajendra@iitmandi.ac.in.
Förderung
- ANRF
Zitieren
APA
Shrivastava, K., Kumar, A., Hiremath, S. S., Kourmatzis, A., & Singh, G. (2026). Comparing a Fixed and Freely Rotating Capsule in a Dry Powder Inhaler Under Realistic Breathing Conditions. Pharmaceutical Research, 43(10), 3849-3862. https://doi.org/10.1007/s11095-026-04184-3
Vancouver
Shrivastava K, Kumar A, Hiremath SS, Kourmatzis A, Singh G. Comparing a Fixed and Freely Rotating Capsule in a Dry Powder Inhaler Under Realistic Breathing Conditions. Pharmaceutical Research. 2026;43(10):3849-3862. doi:10.1007/s11095-026-04184-3
BibTeX
@article{Shrivastava2026,
author = {Shrivastava, Karan and Kumar, Ajit and Hiremath, Somashekhar S and Kourmatzis, Agisilaos and Singh, Gajendra},
title = {Comparing a Fixed and Freely Rotating Capsule in a Dry Powder Inhaler Under Realistic Breathing Conditions},
journal = {Pharmaceutical Research},
year = {2026},
volume = {43},
number = {10},
pages = {3849--3862},
doi = {10.1007/s11095-026-04184-3}
}
EUVIMED