EUVIMEDEUVIMED entdecken
Crossref

Regional Extrathoracic Deposition of Inhaled Epinephrine in an Idealized Child Airway: Influence of Pressurized Metered Dose Inhaler Actuator Orifice Diameter

Kineshta Pillay, Scott Tavernini, Conor A Ruzycki, George H Luciuk, Kevin W Stapleton, Warren H Finlay, Andrew R Martin

Pharmaceutical Research · 2026-04 · 43 (4) · 1131-1140

DOI: 10.1007/s11095-026-04048-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutical Research, online erschienen am 20.02.2026. Verfasst von Kineshta Pillay und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada. Hauptthemen laut MEDLINE: Metered Dose Inhalers, Epinephrine, Bronchodilator Agents. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Kokua Pharma Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The actuator orifice diameter (OD) of pressurized metered dose inhalers (pMDIs) is known to influence the plume geometry and spray pattern exiting the orifice. Actuator OD has previously been found to influence in vitro regional deposition in an adult extrathoracic airway model for a suspension epinephrine formulation, with smaller OD reducing oral cavity deposition. Whether this effect persists in the smaller extrathoracic airways of school-aged children is unknown. METHODS: Regional extrathoracic deposition of epinephrine from pMDIs was investigated using an idealized child mouth-throat geometry. A sectioned version of the Alberta Idealized Child Throat (AICT), divided into analogues of the oral cavity, the pharynx/larynx, and the upper trachea, was used to test pMDIs with small and large ODs (0.22 and 0.44 mm) across a range of inhalation flowrates (10, 30, 60, and 100 L/min), with two inhaler insertion angles (transverse and coaxial). In addition, the effect of increasing ambient humidity on regional extrathoracic deposition was explored with both actuator ODs. RESULTS: Actuator OD strongly influenced in vitro regional extrathoracic deposition in the child model, with the smaller OD decreasing oral cavity deposition, and increasing delivery to the laryngeal region and lungs. While increased ambient humidity influenced in vitro regional extrathoracic deposition, the influence of environmental changes was minor when compared with changes associated with actuator OD. CONCLUSION: Overall, for the suspension epinephrine formulation tested, the reduction in oral cavity deposition observed for the smaller OD actuator was maintained despite varying extrathoracic airway size (child vs. adult) and varying ambient humidity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metered Dose InhalersEpinephrineBronchodilator AgentsHumansAdministration, InhalationChildPharynxEquipment DesignHumidityModels, AnatomicTracheaMouth

Stichwörter der Autor:innen

airway modelinhaled epinephrinemetered dose inhalerpediatricregional deposition

Substanzen

EpinephrineBronchodilator Agents

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada.
  • Atmose Ltd, Edmonton, AB, Canada.
  • Kokua Pharma Inc., Richmond, BC, Canada.
  • Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada. andrew.martin@ualberta.ca.
  • Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada. andrew.martin@ualberta.ca.

Förderung

  • Kokua Pharma Inc

Zitieren

APA

Pillay, K., Tavernini, S., Ruzycki, C. A., Luciuk, G. H., Stapleton, K. W., Finlay, W. H., & Martin, A. R. (2026). Regional Extrathoracic Deposition of Inhaled Epinephrine in an Idealized Child Airway: Influence of Pressurized Metered Dose Inhaler Actuator Orifice Diameter. Pharmaceutical Research, 43(4), 1131-1140. https://doi.org/10.1007/s11095-026-04048-w

Vancouver

Pillay K, Tavernini S, Ruzycki CA, Luciuk GH, Stapleton KW, Finlay WH, et al. Regional Extrathoracic Deposition of Inhaled Epinephrine in an Idealized Child Airway: Influence of Pressurized Metered Dose Inhaler Actuator Orifice Diameter. Pharmaceutical Research. 2026;43(4):1131-1140. doi:10.1007/s11095-026-04048-w

BibTeX
@article{Pillay2026,
  author = {Pillay, Kineshta and Tavernini, Scott and Ruzycki, Conor A and Luciuk, George H and Stapleton, Kevin W and Finlay, Warren H and Martin, Andrew R},
  title = {Regional Extrathoracic Deposition of Inhaled Epinephrine in an Idealized Child Airway: Influence of Pressurized Metered Dose Inhaler Actuator Orifice Diameter},
  journal = {Pharmaceutical Research},
  year = {2026},
  volume = {43},
  number = {4},
  pages = {1131--1140},
  doi = {10.1007/s11095-026-04048-w}
}
Kostenlos starten →