EUVIMEDEUVIMED entdecken
Crossref

Optimal gold and oxide coating selection for a novel dual-elliptical channel PCF sensor for concurrent detection of two distinct analytes

Md. Tanvir Hossain, Md. Arafat Rahman, Abror Jawad

Optical and Quantum Electronics · 20.06.2026 · 58 (9)

DOI: 10.1007/s11082-026-08957-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optical and Quantum Electronics, online erschienen am 20.06.2026. Verfasst von Md. Tanvir Hossain und 2 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Our research introduces a unique refractive index (RI) biosensor utilizing surface plasmon resonance (SPR) for the detection of cancerous cells. The sensor design incorporates two elliptical channels, two elliptical air holes, and four circular air holes, ensuring manufacturing simplicity. Gold (Au) is employed as the plasmonic layer, while Tantalum Pentoxide (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{Ta}_2\textrm{O}_5$$\end{document}) is selected as the oxide coating owing to its superior performance in enhancing analyte interaction. The proposed PCF-SPR structure benefits from two large elliptical air holes, reducing fabrication complexity and minimizing light leakage. Its performance is numerically investigated using the finite element method (FEM). Optimized structural parameters yield a maximum wavelength sensitivity (WS) of 10,000 nm/RIU and 19,000 nm/RIU for channels 1 and 2, respectively. The highest amplitude sensitivity (AS) reaches 374.35 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{RIU}^{-1}$$\end{document} and 888.52 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{RIU}^{-1}$$\end{document}, with peak figures of merit (FOM) of 135 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{RIU}^{-1}$$\end{document} in ch-1 and 179 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{RIU}^{-1}$$\end{document} in ch-2. When both channels are filled with the same analyte, the sensor demonstrates a remarkable WS of 18,000 nm/RIU, angular sensitivity of 1456.29 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{RIU}^{-1}$$\end{document}, and FOM of 274 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{RIU}^{-1}$$\end{document}, along with a broad RI detection range of 1.28−1.42. Furthermore, it efficiently detects malignant cells, achieving a maximum WS of 11,000 nm/RIU with a wavelength resolution of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$9.09 \times 10^{-6}$$\end{document}RIU for cervical (HeLa) cells. The proposed biosensor, with dual-channel analyte sensing, broad RI range, and outstanding sensitivity, offers potential for simultaneous detection of biomolecules, glucose, carcinogenic substances, and other chemical compounds.

Zitieren

APA

Hossain, M. T., Rahman, M. A., & Jawad, A. (2026). Optimal gold and oxide coating selection for a novel dual-elliptical channel PCF sensor for concurrent detection of two distinct analytes. Optical and Quantum Electronics, 58(9). https://doi.org/10.1007/s11082-026-08957-3

Vancouver

Hossain MT, Rahman MA, Jawad A. Optimal gold and oxide coating selection for a novel dual-elliptical channel PCF sensor for concurrent detection of two distinct analytes. Optical and Quantum Electronics. 2026;58(9). doi:10.1007/s11082-026-08957-3

BibTeX
@article{Hossain2026,
  author = {Hossain, Md. Tanvir and Rahman, Md. Arafat and Jawad, Abror},
  title = {Optimal gold and oxide coating selection for a novel dual-elliptical channel PCF sensor for concurrent detection of two distinct analytes},
  journal = {Optical and Quantum Electronics},
  year = {2026},
  volume = {58},
  number = {9},
  doi = {10.1007/s11082-026-08957-3}
}
Kostenlos starten →