Evaluating applied force reduced-order models: validation
Nonlinear Dynamics · 2026-08 · 114 (15)
DOI: 10.1007/s11071-026-12844-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nonlinear Dynamics, online erschienen am 05.08.2026. Verfasst von Max de Bono und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bristol.
Abstract (Originalsprache)
Reduced-order modelling describes a powerful set of techniques for dramatically reducing the cost of dynamic simulations in complex engineering systems, with broad application for designing and understanding nonlinearity. For Reduced-Order Models (ROMs) to be useful in an industrial context, an analyst must have a high degree of confidence that the results reported by the ROM are reflective of the full-order system. Typically, some full-order results are required to demonstrate the accuracy of a particular ROM. For large and complex systems, this will significantly undercut the initial computational motivations for creating said ROM in the first place. This work presents a novel, full-order simulation-free validation method for applied force ROMs of conservative, geometrically nonlinear systems. This is achieved by testing prospective results to see if they could exist in a series of larger ROMs. If they can, then the smaller ROM has sufficiently approximated the relevant section of the full-order invariant manifold. This allows potential reduction bases to be rapidly tested and a valid, ideally small, basis chosen. This is especially valuable in an applied force context where any low-frequency mode could be required in the reduction basis. A two degree-of-freedom ROM, describing a 100,000 degree-of-freedom finite element model of a curved double arch exhibiting internal resonance, is constructed and fully validated in under 15 min on a desktop computer. Refining the mesh such that there are 1,000,000 degrees-of-freedom increases this time to 170 min. Equivalent full-order simulation validation would take days. Furthermore, no a priori assumption is made about the nature or even the presence of the internal resonance, which is not the case for other reduced-order approaches. This is an important step towards accessible and automatable reduced-order modelling software.
Förderung
- University of Bristol
Zitieren
APA
Bono, M. D., Hill, T. L., & Groh, R. M. J. (2026). Evaluating applied force reduced-order models: validation. Nonlinear Dynamics, 114(15). https://doi.org/10.1007/s11071-026-12844-7
Vancouver
Bono MD, Hill TL, Groh RMJ. Evaluating applied force reduced-order models: validation. Nonlinear Dynamics. 2026;114(15). doi:10.1007/s11071-026-12844-7
BibTeX
@article{Bono2026,
author = {Bono, Max de and Hill, Thomas L. and Groh, Rainer M. J.},
title = {Evaluating applied force reduced-order models: validation},
journal = {Nonlinear Dynamics},
year = {2026},
volume = {114},
number = {15},
doi = {10.1007/s11071-026-12844-7}
}