Hypoxia-targeted BOLD MRI signal heterogeneity as a complementary metric for glioblastoma characterization: a pilot study
Journal of Neuro-Oncology · 2026-09 · 179 (2)
DOI: 10.1007/s11060-026-05762-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuro-Oncology, online erschienen am 20.08.2026. Verfasst von Leonie Zerweck und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich and University of Zurich, Zurich, Switzerland. leonie.zerweck@us…. Hauptthemen laut MEDLINE: Glioblastoma, Brain Neoplasms, Magnetic Resonance Imaging, Oxygen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Zurich.
Abstract (Originalsprache)
Purpose
Hypoxia-targeted blood oxygen level–dependent (BOLD) MRI is an emerging non-contrast imaging technique for characterizing tumor biology in isocitrate dehydrogenase-wildtype glioblastoma. Beyond the magnitude of BOLD signal changes, signal heterogeneity may provide valuable information about tumor aggressiveness and microenvironmental complexity. The aim was to assess both the magnitude and heterogeneity of hypoxia-targeted BOLD signal changes across subregions of glioblastomas.
Methods
In this prospective pilot study, hypoxia-targeted BOLD MRI data from 12 patients with histopathologically confirmed glioblastoma were analyzed. Tumor subregions were defined using an automated segmentation framework (Oncohabitats) based on conventional MRI and dynamic susceptibility contrast (DSC) MR perfusion imaging. Voxel-wise BOLD signal changes were calculated within the following volumes of interest: highly angiogenic tumor (HAT), low angiogenic tumor (LAT), peritumoral edema, and mirrored contralateral control tissue (mCET). The magnitude of BOLD signal changes was assessed using median BOLD signal changes, while heterogeneity was quantified using interquartile ranges (IQR), and kernel density estimation-derived entropy. Friedman tests with Dunn post-hoc tests were used to assess parameter differences between the VOIs.
Results
HAT demonstrated the largest BOLD signal changes compared with LAT, edema, and mCET (all FDR-adjusted p ≤ 0.017). Heterogeneity metrics revealed significantly increased IQR and entropy in HAT compared with edema and mCET (all FDR-adjusted p < 0.008), with LAT showing intermediate values.
Conclusion
Hypoxia-targeted BOLD MRI reveals both greater BOLD signal changes and elevated intratumoral heterogeneity in highly angiogenic and likely aggressive glioblastoma subregions. These findings suggest that heterogeneity metrics may provide complementary information to BOLD signal magnitude alone.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich and University of Zurich, Zurich, Switzerland. leonie.zerweck@usz.ch.
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Tuebingen, Germany. leonie.zerweck@usz.ch.
- Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
- Department of Neurology, Clinical Neuroscience Center, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
Förderung
- University of Zurich
Zitieren
APA
Zerweck, L., Schmidlechner, T., Stumpo, V., Jehli, E., Gönel, M., Müller, F., Bellomo, J., Sebök, M., Bink, A., Kulcsár, Z., Weller, M., Regli, L., van Niftrik, C. H. B., & Fierstra, J. (2026). Hypoxia-targeted BOLD MRI signal heterogeneity as a complementary metric for glioblastoma characterization: a pilot study. Journal of Neuro-Oncology, 179(2). https://doi.org/10.1007/s11060-026-05762-6
Vancouver
Zerweck L, Schmidlechner T, Stumpo V, Jehli E, Gönel M, Müller F, et al. Hypoxia-targeted BOLD MRI signal heterogeneity as a complementary metric for glioblastoma characterization: a pilot study. Journal of Neuro-Oncology. 2026;179(2). doi:10.1007/s11060-026-05762-6
BibTeX
@article{Zerweck2026,
author = {Zerweck, Leonie and Schmidlechner, Tristan and Stumpo, Vittorio and Jehli, Elisabeth and Gönel, Meltem and Müller, Flavia and Bellomo, Jacopo and Sebök, Martina and Bink, Andrea and Kulcsár, Zsolt and Weller, Michael and Regli, Luca and van Niftrik, Christiaan H B and Fierstra, Jorn},
title = {Hypoxia-targeted BOLD MRI signal heterogeneity as a complementary metric for glioblastoma characterization: a pilot study},
journal = {Journal of Neuro-Oncology},
year = {2026},
volume = {179},
number = {2},
doi = {10.1007/s11060-026-05762-6}
}
EUVIMED