Optimization of novel exoscopic blue light filter during fluorescence-guided resection of Glioblastoma
Journal of Neuro-Oncology · 2023
DOI: 10.1007/s11060-022-04231-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuro-Oncology, 2023. Verfasst von Andrew J Witten und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurological Surgery, Indiana University, Indianapolis, IN, 46202, USA. Hauptthemen laut MEDLINE: Glioblastoma, Brain Neoplasms, Surgery, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Operative guidelines and use optimization for new surgical exoscopes are not well described in the literature. In this study, we evaluated use of the ORBEYE (Olympus) surgical exoscope system during 5-ALA fluorescence-guided resection of GBMs to optimize workflow and exoscope settings. METHODS: The ORBEYE exoscope system was fitted with a blue light filter for 5-ALA mediated fluorescence-guided surgery (FGS). Intraoperative images were obtained during 5-ALA FGS in 9 patients with primary or recurrent GBM. The exoscope was set up at constant, increasing focal distances from the target tissue, and light source intensity varied. High-resolution 4 K images were captured and analyzed. Comparisons of fluorescence to background were then generated for use optimization. RESULTS: Light intensity did not significantly influence tumor fluorescence (P = 0.878). However, focal distance significantly impacted relative fluorescent intensity (P = 0.007). Maximum average fluorescence was seen consistently at a focal length of 220 mm and a light intensity of approximately 75% maximum. Decreasing focal distance from 400 mm to 220 mm significantly increased visualized fluorescence (P = 0.0038). CONCLUSIONS: The ORBEYE surgical exoscope system with blue light filter is a powerful imaging tool for 5-ALA FGS in GBM. The ORBEYE blue filter performs optimally at shorter focal distance with moderate light intensity. Similar to microscope systems, decreasing focal distance significantly influences visualized fluorescence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurological Surgery, Indiana University, Indianapolis, IN, 46202, USA.
- Department of Neurological Surgery, Lenox Hill Hospital/Donald and Barbara Zucker School of Medicine at Hofstra, New York, NY, USA.
- Department of Neurological Surgery, Lenox Hill Hospital/Donald and Barbara Zucker School of Medicine at Hofstra, New York, NY, USA. rdamico8@northwell.edu.
Zitieren
APA
Witten, A. J., Ben-Shalom, N., Ellis, J. A., Boockvar, J. A., & D'Amico, R. S. (2023). Optimization of novel exoscopic blue light filter during fluorescence-guided resection of Glioblastoma. Journal of Neuro-Oncology. https://doi.org/10.1007/s11060-022-04231-0
Vancouver
Witten AJ, Ben-Shalom N, Ellis JA, Boockvar JA, D'Amico RS. Optimization of novel exoscopic blue light filter during fluorescence-guided resection of Glioblastoma. Journal of Neuro-Oncology. 2023. doi:10.1007/s11060-022-04231-0
BibTeX
@article{Witten2023,
author = {Witten, Andrew J and Ben-Shalom, Netanel and Ellis, Jason A and Boockvar, John A and D'Amico, Randy S},
title = {Optimization of novel exoscopic blue light filter during fluorescence-guided resection of Glioblastoma},
journal = {Journal of Neuro-Oncology},
year = {2023},
doi = {10.1007/s11060-022-04231-0}
}
EUVIMED