Fire-induced splitting failure in the bond of deformed steel bars: effect of cement type
Journal of Thermal Analysis and Calorimetry · 19.11.2026
DOI: 10.1007/s10973-026-16616-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Thermal Analysis and Calorimetry, online erschienen am 19.11.2026. Verfasst von Ahmed Ali und 1 weiteren Autor:innen. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Budapest University of Technology and Economics.
Abstract (Originalsprache)
Post-fire bond performance of reinforced concrete is commonly evaluated using residual bond strength derived from pull-out-controlled tests; however, fire-induced cracking often promotes splitting-controlled failure, which limits the bond capacity that can be effectively mobilized in practice. This study investigates the influence of cement composition on post-fire bond behavior, with particular emphasis on failure mode transition and on effective bond capacity governed by cover splitting. Four concrete mixtures with identical nominal mix proportions were considered, comprising two slag-containing cement systems (CEM II/A-S 42.5 N and CEM III/B 32.5 N-LH/SR) and two reference systems (CEM I 42.5 N and CEM II/A-LL 42.5 N). Cylindrical pull-out specimens (120 × 100 mm) with a bonded length of 30 mm were exposed to 150, 400, 500, and 800 °C following the ISO 834 fire curve, held for two hours, and air-cooled before testing. The results show that increasing thermal exposure led to a transition from pull-out to splitting-controlled failure between 400 and 500 °C, even when relatively high peak forces were mobilized at 400 °C. The stronger association between residual effective bond capacity and flexural strength than with compressive strength suggests that post-fire bond performance is strongly influenced by the cracking resistance and fracture behavior of the concrete matrix under splitting-controlled conditions. CEM III/B exhibited an effective bond retention of 97% at 150 °C, while the reference CEM II/A-LL system retained 98% and 64% at 400 and 500 °C, respectively. At 800 °C, all mixes exhibited severe degradation, with an effective bond strength of less than 7%, indicating a near-complete loss of bond strength. The results provide experimental evidence on the influence of cement type on post-fire bond behavior and failure characteristics in reinforced concrete.
Förderung
- Budapest University of Technology and Economics
Zitieren
APA
Ali, A., & Lublóy, É. (2026). Fire-induced splitting failure in the bond of deformed steel bars: effect of cement type. Journal of Thermal Analysis and Calorimetry. https://doi.org/10.1007/s10973-026-16616-8
Vancouver
Ali A, Lublóy É. Fire-induced splitting failure in the bond of deformed steel bars: effect of cement type. Journal of Thermal Analysis and Calorimetry. 2026. doi:10.1007/s10973-026-16616-8
BibTeX
@article{Ali2026,
author = {Ali, Ahmed and Lublóy, Éva},
title = {Fire-induced splitting failure in the bond of deformed steel bars: effect of cement type},
journal = {Journal of Thermal Analysis and Calorimetry},
year = {2026},
doi = {10.1007/s10973-026-16616-8}
}
EUVIMED