Clinical Validation of Apollo™, A Novel Web-Based Tool for Refractive Error Self-Assessment
Journal of Medical Systems · 28.03.2026 · 50 (1)
DOI: 10.1007/s10916-026-02369-2 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Medical Systems, online erschienen am 28.03.2026. Verfasst von Rafael Lani-Louzada und 10 weiteren Autor:innen. Beteiligte Einrichtung: Eyecare Health Company, Sao Paulo, SP, Brazil. Hauptthemen laut MEDLINE: Refractive Errors, Internet. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Refractive errors are a leading cause of visual impairment, with substantial economic impact. Digital refraction systems may help improve access to eye care, especially for underserved populations. Considering their relevance, this study evaluated the Apollo™, a novel web-based system for self-assessed refractive error measurement, in estimating spherical equivalent (SEQ) compared to manifest refraction (also known as dry refraction or dynamic refraction) performed by experienced ophthalmologists. A prospective, single-center, single-blind, non-randomized study was conducted with 63 eyes of 64 healthy adults aged 18-40 years. Each participant underwent both manifest subjective refraction and digital refraction using Apollo™. Exclusion criteria included astigmatism exceeding 3.00 diopters (D) in absolute value and SEQ beyond - 4.00 D to + 4.00 D. Primary outcome was the comparison of SEQ between methods. No significant difference was observed between SEQ from Apollo™ (mean - 1.20 ± 1.11 D) and manifest refraction (mean - 1.17 ± 1.14 D; p = 0.67). Bland-Altman analysis showed a bias of 0.03 ± 0.90 D, with 95% limits of agreement (LOA) from - 1.73 to 1.78 D. LOA was narrower in myopic SEQ stratum (-1.48 to 1.35D). The ICC for the total sample SEQ was 0.69 (95% CI: 0.52-0.79), and for the myopic SEQ subgroup was 0.74 (95% CI: 0.58-0.84), indicating moderate to good reliability. The accuracy for detecting the sign of SEQ was 82.5% in the overall cohort and 96.2% in the myopic subgroup. Regression analysis revealed a proportional bias, with the system tending to underestimate refractive error as the magnitude of myopia increases (β = -0.27, p = 0.005). In conclusion, Apollo™ demonstrates moderate-to-good reliability and high diagnostic accuracy (96%) in categorizing refractive status among myopes. These results highlight its potential as a valuable digital screening tool, warranting further large-scale studies to refine its predictive algorithm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Eyecare Health Company, Sao Paulo, SP, Brazil.
- Hospital Israelita Albert Einstein, Albert Einstein Avenue, 627, São Paulo, SP, 05652-900, Brazil. bio.jandrades@gmail.com.
- Hospital Israelita Albert Einstein, Albert Einstein Avenue, 627, São Paulo, SP, 05652-900, Brazil.
Zitieren
APA
Lani-Louzada, R., Negreiros, M. A., Andrade-Silva, J., Ribeiro, L. Z., Pimentel, L. G. M., Souza, R. G., Engelbrecht, C., Neves, D. G., de Andrade Lessa, D., Lottenberg, C. L., & Yasaki, E. S. (2026). Clinical Validation of Apollo™, A Novel Web-Based Tool for Refractive Error Self-Assessment. Journal of Medical Systems, 50(1). https://doi.org/10.1007/s10916-026-02369-2
Vancouver
Lani-Louzada R, Negreiros MA, Andrade-Silva J, Ribeiro LZ, Pimentel LGM, Souza RG, et al. Clinical Validation of Apollo™, A Novel Web-Based Tool for Refractive Error Self-Assessment. Journal of Medical Systems. 2026;50(1). doi:10.1007/s10916-026-02369-2
BibTeX
@article{LaniLouzada2026,
author = {Lani-Louzada, Rafael and Negreiros, Marco Antonio and Andrade-Silva, Jessica and Ribeiro, Lucas Zago and Pimentel, Luis Guilherme Milesi and Souza, Rodrigo Guimarães de and Engelbrecht, Carolina and Neves, Deangelo Gomes and de Andrade Lessa, Daniel and Lottenberg, Cláudio Luiz and Yasaki, Erika Sayuri},
title = {Clinical Validation of Apollo™, A Novel Web-Based Tool for Refractive Error Self-Assessment},
journal = {Journal of Medical Systems},
year = {2026},
volume = {50},
number = {1},
doi = {10.1007/s10916-026-02369-2}
}
EUVIMED