The Influence of Audible Alarm Loudness and Type on Clinical Multitasking
Journal of Medical Systems · 2022-01 · 46 (1)
DOI: 10.1007/s10916-021-01794-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Systems, online erschienen am 23.11.2021. Verfasst von Alexandra L Bruder und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Vanderbilt University Medical Center, 1211 21st Avenue South, Medical Arts Building, Suite 422, Nashville, TN, 37212, U…. Hauptthemen laut MEDLINE: Clinical Alarms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 61 Literaturangaben.
Abstract (Originalsprache)
In high-consequence industries such as health care, auditory alarms are an important aspect of an informatics system that monitors patients and alerts providers attending to multiple concurrent tasks. Alarms levels are unnecessarily high and alarm signals are uninformative. In a laboratory-based task setting, we studied 25 anesthesiology residents' responses to auditory alarms in a multitasking paradigm comprised of three tasks: patient monitoring, speech perception/intelligibility, and visual vigilance. These tasks were in the presence of background noise plus/minus music, which served as an attention-diverting stimulus. Alarms signified clinical decompensation and were either conventional alarms or a novel informative auditory icon alarm. Both alarms were presented at four different levels. Task performance (accuracy and response times) were analyzed using logistic and linear mixed-effects regression. Salient findings were 1), the icon alarm had similar performance to the conventional alarm at a +2 dB signal-to-noise-ratio (SNR) (accuracy: OR 1.21 (95% CI 0.88, 1.67), response time: 0.04 s at 2 dB (95% CI: -0.16, 0.24), which is a much lower level than current clinical environments; 2) the icon alarm was associated with 27% greater odds (95% CI: 18%, 37%) of correctly addressing the vigilance task, regardless of alarm SNR, suggesting crossmodal/multisensory multitasking benefits; and 3) compared to the conventional alarm, the icon alarm was associated with an absolute improvement in speech perception of 4% in the presence of an attention-diverting auditory stimulus (p = 0.031). These findings suggest that auditory icons can provide multitasking benefits in cognitively demanding clinical environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Vanderbilt University Medical Center, 1211 21st Avenue South, Medical Arts Building, Suite 422, Nashville, TN, 37212, USA. alexandra.l.bruder@vanderbilt.edu.
- Department of Biomedical Informatics, The Ohio State University, 460 Medical Center Drive, Suite 526, Columbus, OH, 43210, USA.
- School of Medicine, University of Virginia, 1215 Lee Street, Charlottesville, VA, 22908, USA.
- Department of Biostatistics, Vanderbilt University, 2525 West End Avenue, Nashville, TN, 37212, USA.
- School of Psychology, University of Plymouth, Drake Circus, Plymouth, PL4 8AA, UK.
- Department of Anesthesiology, Vanderbilt University Medical Center, 1211 21st Avenue South, Medical Arts Building, Suite 422, Nashville, TN, 37212, USA.
Zitieren
APA
Bruder, A. L., Rothwell, C. D., Fuhr, L. I., Shotwell, M. S., Edworthy, J. R., & Schlesinger, J. J. (2022). The Influence of Audible Alarm Loudness and Type on Clinical Multitasking. Journal of Medical Systems, 46(1). https://doi.org/10.1007/s10916-021-01794-9
Vancouver
Bruder AL, Rothwell CD, Fuhr LI, Shotwell MS, Edworthy JR, Schlesinger JJ. The Influence of Audible Alarm Loudness and Type on Clinical Multitasking. Journal of Medical Systems. 2022;46(1). doi:10.1007/s10916-021-01794-9
BibTeX
@article{Bruder2022,
author = {Bruder, Alexandra L and Rothwell, Clayton D and Fuhr, Laura I and Shotwell, Matthew S and Edworthy, Judy Reed and Schlesinger, Joseph J},
title = {The Influence of Audible Alarm Loudness and Type on Clinical Multitasking},
journal = {Journal of Medical Systems},
year = {2022},
volume = {46},
number = {1},
doi = {10.1007/s10916-021-01794-9}
}
EUVIMED