EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-degenerate Pumping of Superconducting Resonator Parametric Amplifier with Evidence of Phase-Sensitive Amplification

Songyuan Zhao, S Withington, C N Thomas

Journal of Low Temperature Physics · 09.04.2026 · 222 (2)

DOI: 10.1007/s10909-026-03407-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Low Temperature Physics, online erschienen am 09.04.2026. Verfasst von Songyuan Zhao und 2 weiteren Autor:innen. Beteiligte Einrichtung: Clarendon Laboratory, Parks Road, Oxford, OX1 3PU UK. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Facilities Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Superconducting resonator parametric amplifiers are potentially important components for a wide variety of fundamental physics experiments and utilitarian applications. We propose and realise an operating scheme that achieves amplification through the use of non-degenerate pumps, which addresses two key challenges in the design of parametric amplifiers: non-continuous gain across the amplification band and pump tone removal. We have experimentally demonstrated the non-degenerate pumping scheme using a half-wave resonator amplifier based on NbN thin-film, and measured a peak gain of 26 dB and 3-dB bandwidth of 0.5 MHz. The two non-degenerate pump tones were positioned $$\sim 10$$ ∼ 10 bandwidths above and below the frequency at which peak gain occurs. We have found the non-degenerate pumping scheme to be more stable compared to the usual degenerate pumping scheme in terms of gain drift over time, by a factor of 4. This scheme also retains the usual flexibility of NbN resonator parametric amplifiers in terms of reliable amplification in a $$\sim 4$$ ∼ 4 K environment, and is suitable for cross-harmonic amplification. The use of pump tones at different frequencies allows phase-sensitive amplification when the signal tone is degenerate with the idler tone. A gain of 23 dB and squeezing ratio of 6 dB were measured.

Schlagwörter

Stichwörter der Autor:innen

Kinetic inductanceParametric amplifiersPhase-sensitive amplificationSqueezingSuperconducting resonators

Autor:innen und Institutionen

  • Clarendon Laboratory, Parks Road, Oxford, OX1 3PU UK.
  • Cavendish Laboratory, JJ Thomson Avenue, Cambridge, CB3 OHE UK.

Förderung

  • Science and Technology Facilities Council

Zitieren

APA

Zhao, S., Withington, S., & Thomas, C. N. (2026). Non-degenerate Pumping of Superconducting Resonator Parametric Amplifier with Evidence of Phase-Sensitive Amplification. Journal of Low Temperature Physics, 222(2). https://doi.org/10.1007/s10909-026-03407-6

Vancouver

Zhao S, Withington S, Thomas CN. Non-degenerate Pumping of Superconducting Resonator Parametric Amplifier with Evidence of Phase-Sensitive Amplification. Journal of Low Temperature Physics. 2026;222(2). doi:10.1007/s10909-026-03407-6

BibTeX
@article{Zhao2026,
  author = {Zhao, Songyuan and Withington, S and Thomas, C N},
  title = {Non-degenerate Pumping of Superconducting Resonator Parametric Amplifier with Evidence of Phase-Sensitive Amplification},
  journal = {Journal of Low Temperature Physics},
  year = {2026},
  volume = {222},
  number = {2},
  doi = {10.1007/s10909-026-03407-6}
}
Kostenlos starten →