EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Experimental Study of a Thermosiphon-Based Passive Heat Switch in an Integrated Adiabatic Demagnetization and Dilution Refrigerator System

Byeungcheol An, Minseung Ku, Jaehwan Jeong, Sangkwon Jeong

Journal of Low Temperature Physics · 01.04.2026 · 222 (2)

DOI: 10.1007/s10909-026-03388-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Low Temperature Physics, online erschienen am 01.04.2026. Verfasst von Byeungcheol An und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea Advanced Institute of Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study proposes a thermal connection/isolation strategy to achieve less than 1 K pre-cooling required for Dilution Refrigerator (DR) operation in an integrated cryogenic system composed of a 4 K GM cryocooler, evaporative cooler, an Adiabatic Demagnetization Refrigerator (ADR), and a DR. We install a gravity-assisted thermosiphon-based passive heat switch (PHS) above the Gadolinium Gallium Garnet ADR stage, above the Still, and above the Mixing Chamber (MXC). An energy-balance model was used to estimate the attainable temperatures of the refrigeration chain, whereas convection and conduction models were used to design the PHS. In the OFF mode, considering conduction, the lower boundary warms from 2.2 K to 3.0 K in approximately 1.7 h, and the initial conduction heat inflow is estimated at ~ 319 μW—sufficiently low relative to the preparation time between cycles, indicating adequate thermal isolation. In the ON mode, a natural-convection correlation yields an effective heat transport of 11 mW, corresponding to a switching performance ratio about 36 times higher than in the OFF state. Experimentally, the Still pressure of 1.6 kPa was achieved, confirming the conceptual validity of the thermosiphon PHS. These results provide practical guidance for DR-interface design and robust pre-cooling in systems with small He-3 inventory, especially when combined with MXC pre-cooling pathway optimization and reduction of parasitic heat loads.

Förderung

  • National Research Foundation of Korea
  • Korea Advanced Institute of Science and Technology

Zitieren

APA

An, B., Ku, M., Jeong, J., & Jeong, S. (2026). Design and Experimental Study of a Thermosiphon-Based Passive Heat Switch in an Integrated Adiabatic Demagnetization and Dilution Refrigerator System. Journal of Low Temperature Physics, 222(2). https://doi.org/10.1007/s10909-026-03388-6

Vancouver

An B, Ku M, Jeong J, Jeong S. Design and Experimental Study of a Thermosiphon-Based Passive Heat Switch in an Integrated Adiabatic Demagnetization and Dilution Refrigerator System. Journal of Low Temperature Physics. 2026;222(2). doi:10.1007/s10909-026-03388-6

BibTeX
@article{An2026,
  author = {An, Byeungcheol and Ku, Minseung and Jeong, Jaehwan and Jeong, Sangkwon},
  title = {Design and Experimental Study of a Thermosiphon-Based Passive Heat Switch in an Integrated Adiabatic Demagnetization and Dilution Refrigerator System},
  journal = {Journal of Low Temperature Physics},
  year = {2026},
  volume = {222},
  number = {2},
  doi = {10.1007/s10909-026-03388-6}
}
Kostenlos starten →