EUVIMEDEUVIMED entdecken
Crossref

Isoniazid-Derived Schiff Base Chemosensor for Dual-Mode Detection of Metal Ions and Bio-imaging Applications

Pooja Meena, Priyanka Surya, Ved Prakash Meena, Anita Kumari, Prabhat Ranjan, Sweta Singh, Ramhari Meena

Journal of Fluorescence · 27.04.2026 · 36 (5) · 3419-3434

DOI: 10.1007/s10895-026-04774-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fluorescence, online erschienen am 27.04.2026. Verfasst von Pooja Meena und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Rajasthan, Jaipur, Rajasthan, 302004, India. Hauptthemen laut MEDLINE: Copper, Nickel. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 65 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study discusses a Schiff base chemosensor ((E)-N’-(2-hydroxybenzylidene)isonicotinohydrazide (HISN)), specifically designed for the rapid detection of Cu²⁺ and Ni²⁺ ions in aqueous medium. HISN characterization was conducted using various methods, including FT-IR, HRMS, ¹H NMR, ¹³C NMR, fluorometric techniques, and UV-Visible spectroscopy. In an acetonitrile solution (1 µM, pH = 7.4), HISN exhibited a noticeable and significant color change from colorless to yellow when exposed to Cu²⁺ and Ni²⁺ ions. The UV-visible absorption spectrum of the HISN-Cu²⁺ and HISN-Ni²⁺ complexes displayed both bathochromic (red) and hypsochromic (blue) shifts. Additionally, the presence of Cu²⁺ and Ni²⁺ ions notably increased the fluorescence intensity of HISN. The limits of detection (LOD) and quantification (LOQ) for HISN with respect to Cu²⁺ and Ni²⁺ ions were established. The LOD values are 3.394 × 10− 9 M for Cu²⁺ and 1.646 × 10− 7 M for Ni²⁺, while the corresponding LOQ values are 1.131 × 10− 8 M for Cu²⁺ and 5.487 × 10− 7 M for Ni²⁺. Data analysis from Job’s plot, along with HRMS and FT-IR spectral data, suggested a 1:1 stoichiometric relationship between HISN and both Cu²⁺ and Ni²⁺ ions. Further, the complex formation between HISN-Cu2+ and HISN-Ni2+ was confirmed by Density Functional Theory (DFT) calculations using Gaussian 16 software. Geometry optimization of these complexes is carried out using the exchange-correlation functional B3PW91 and the basis set 6-311 + G(d, p). MTT assay results indicated that HISN formulations are cytocompatible and do not harm cells at varying concentrations. Furthermore, HISN has been utilized as a fluorescent imaging probe for intracellular Cu²⁺and Ni²⁺ ions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperNickelSchiff BasesFluorescent Chemosensor CompoundsHumansMolecular Structure

Stichwörter der Autor:innen

Cell imagingColorimetricCytotoxicityMetal ion sensingSchiff base chemosensor

Substanzen

Schiff BasesCopperNickelFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • Department of Chemistry, University of Rajasthan, Jaipur, Rajasthan, 302004, India.
  • Division of Stem Cell and Gene Therapy Research, Institute of Nuclear Medicine and Allied Sciences, Defence Research and Development Organization, Brig. S.K. Mazumdar Road, Delhi, 110054, India.
  • Department of Chemistry, University of Delhi, Delhi, 110007, India.
  • Department of Mechatronics Engineering, Manipal University Jaipur, Dehmi Kalan, Jaipur, 303007, India.
  • Division of Stem Cell and Gene Therapy Research, Institute of Nuclear Medicine and Allied Sciences, Defence Research and Development Organization, Brig. S.K. Mazumdar Road, Delhi, 110054, India. sweta.raghuvanshi@gmail.…
  • Department of Chemistry, University of Rajasthan, Jaipur, Rajasthan, 302004, India. ramharichem@gmail.com.

Zitieren

APA

Meena, P., Surya, P., Meena, V. P., Kumari, A., Ranjan, P., Singh, S., & Meena, R. (2026). Isoniazid-Derived Schiff Base Chemosensor for Dual-Mode Detection of Metal Ions and Bio-imaging Applications. Journal of Fluorescence, 36(5), 3419-3434. https://doi.org/10.1007/s10895-026-04774-9

Vancouver

Meena P, Surya P, Meena VP, Kumari A, Ranjan P, Singh S, et al. Isoniazid-Derived Schiff Base Chemosensor for Dual-Mode Detection of Metal Ions and Bio-imaging Applications. Journal of Fluorescence. 2026;36(5):3419-3434. doi:10.1007/s10895-026-04774-9

BibTeX
@article{Meena2026,
  author = {Meena, Pooja and Surya, Priyanka and Meena, Ved Prakash and Kumari, Anita and Ranjan, Prabhat and Singh, Sweta and Meena, Ramhari},
  title = {Isoniazid-Derived Schiff Base Chemosensor for Dual-Mode Detection of Metal Ions and Bio-imaging Applications},
  journal = {Journal of Fluorescence},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {3419--3434},
  doi = {10.1007/s10895-026-04774-9}
}
Kostenlos starten →