EUVIMEDEUVIMED entdecken
Crossref

Construction of a Cu2+-Responsive NIR Fluorescent Probe and the Preliminary Evaluation of its Multifunctional Application

Tao Zhang, Huirong Chi, Jingjie Guo, Xinmiao Lu, Guolin Li

Journal of Fluorescence · 2024

DOI: 10.1007/s10895-024-03610-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fluorescence, 2024. Verfasst von Tao Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral, Shanghai Eighth People's Hospital, Xuhui Branch of Shanghai Sixth People's Hospital, Shanghai, 200233, China. Hauptthemen laut MEDLINE: Copper, Fluorescent Dyes, Infrared Rays. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cu2+ was deemed as toxic and the most common heavy metal pollution in the water and food. Meanwhile, endogenous Cu2+ was deeply involved in plenty of physiological and pathological processes of human. Cu2+ imbalance was related to multiple diseases. Here we developed a Cu2+-responsive NIR probe HX, which not only demonstrated obvious color change when subjected to Cu2+, but also showed linear-dependent NIR fluorescence emission to Cu2+ concentration for Cu2+ detection and quantification both in vitro and in vivo. When HX was applied to imaging Cu2+ in the cell or living animals, intracellular Cu2+ fluctuation and Cu2+ accumulation in the liver could be visualized to indicate the copper level in the cell or organs with low background signals. Meanwhile, by applying HX to monitor Cu2+ uptake in the tumor, copper transporter function could be evaluated to screen the patient who are sensitivity to platinum drug.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperFluorescent DyesInfrared RaysHumansAnimalsOptical ImagingMice

Stichwörter der Autor:innen

Copper transporterCu2+Fluorescent probeNear infrared

Substanzen

CopperFluorescent Dyes

Autor:innen und Institutionen

  • Department of Oral, Shanghai Eighth People's Hospital, Xuhui Branch of Shanghai Sixth People's Hospital, Shanghai, 200233, China.
  • Department of Nuclear Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200235, China. luxinmiao@sjtu.edu.cn.
  • Department of Oral, Shanghai Eighth People's Hospital, Xuhui Branch of Shanghai Sixth People's Hospital, Shanghai, 200233, China. liguolin@126.com.
  • Key Laboratory of Microecology-Immune Regulatory Network and Related Diseases, School of Basic Medicine, Jiamusi University, Jiamusi, Heilongjiang, 154000, P. R. China. liguolin@126.com.

Zitieren

APA

Zhang, T., Chi, H., Guo, J., Lu, X., & Li, G. (2024). Construction of a Cu2+-Responsive NIR Fluorescent Probe and the Preliminary Evaluation of its Multifunctional Application. Journal of Fluorescence. https://doi.org/10.1007/s10895-024-03610-2

Vancouver

Zhang T, Chi H, Guo J, Lu X, Li G. Construction of a Cu2+-Responsive NIR Fluorescent Probe and the Preliminary Evaluation of its Multifunctional Application. Journal of Fluorescence. 2024. doi:10.1007/s10895-024-03610-2

BibTeX
@article{Zhang2024,
  author = {Zhang, Tao and Chi, Huirong and Guo, Jingjie and Lu, Xinmiao and Li, Guolin},
  title = {Construction of a Cu2+-Responsive NIR Fluorescent Probe and the Preliminary Evaluation of its Multifunctional Application},
  journal = {Journal of Fluorescence},
  year = {2024},
  doi = {10.1007/s10895-024-03610-2}
}
Kostenlos starten →