EUVIMEDEUVIMED entdecken
Crossref

A Ratiometric Fluorescence Biosensor for Detection of Alkaline Phosphatase Via an Advanced Chemometric Model

Yao Chen, Jing-Jing Han, Bo-Wen Li, Li-Bo Nie, Ying Tang, Tong Wang

Journal of Fluorescence · 2024

DOI: 10.1007/s10895-023-03445-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fluorescence, 2024. Verfasst von Yao Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Key Lab of Biomedical Materials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou, 412007, PR China. Hauptthemen laut MEDLINE: Alkaline Phosphatase, Biosensing Techniques, Benzothiazoles, Fluorescent Dyes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, a ratiometric fluorescence biosensor was introduced for alkaline phosphatase (ALP) detection based on 2-aminopurine (2-Amp) and thioflavin T (ThT)-G-quadruplex system. We designed a special DNA (5'-AGGGTTAGGGTTAGGGTTAGGGAAA/i2-Amp/AAAA-PO4-3', AP) modified with a phosphate moiety at the 3'-end, G-quadruplex at the 5'-end, and a fluorophore (2-Amp) in the middle. In the absence of ALP, the G-rich AP strand could be prone to fold into G-quadruplex structures in the presence of K+. Then, ThT combined with G-quandruplex, resulting in the enhancement of fluorescence emission peak at 485 nm. However, ALP-mediated hydrolysis of the 3'-phosphoryl end promoted the cleavage of AP by the exonuclease I (Exo I), releasing 2-Amp which displayed a strong fluorescence emission peak at 365 nm. Moreover, the quantitative fluorescence model (QFM) was derived for the analysis of the fluorescence measurements obtained by the proposed ratiometric fluorescent biosensor. With the aid of the advanced model, the proposed ratiometric fluorescent biosensor possessed satisfactory results for the detection of ALP in the human serum samples, with accuracy comparable to that of the reference method-the commercial ALP assay kit. Under the optimized experimental conditions, this method exhibited good selectivity and higher sensitivity, and the detection limit was found to be as low as 0.017 U/L. Therefore, it is reasonable to expect that the method had a great potential to detect ALP quantitatively in clinical diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Alkaline PhosphataseBiosensing TechniquesBenzothiazolesFluorescent DyesHumansSpectrometry, FluorescenceG-QuadruplexesFluorescence2-AminopurineDNALimit of Detection

Stichwörter der Autor:innen

Alkaline phosphataseQuantitative fluorescence modelRatiometric fluorescence biosensor

Substanzen

Alkaline Phosphatasethioflavin TBenzothiazolesFluorescent Dyes2-AminopurineDNA

Autor:innen und Institutionen

  • Hunan Key Lab of Biomedical Materials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou, 412007, PR China.
  • State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China.
  • Hunan Key Lab of Biomedical Materials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou, 412007, PR China. yingtang@hnu.edu.cn.
  • State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China. yingtang@hnu.edu.cn.
  • State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China. wangtong@hnu.edu.cn.

Zitieren

APA

Chen, Y., Han, J. J., Li, B. W., Nie, L. B., Tang, Y., & Wang, T. (2024). A Ratiometric Fluorescence Biosensor for Detection of Alkaline Phosphatase Via an Advanced Chemometric Model. Journal of Fluorescence. https://doi.org/10.1007/s10895-023-03445-3

Vancouver

Chen Y, Han JJ, Li BW, Nie LB, Tang Y, Wang T. A Ratiometric Fluorescence Biosensor for Detection of Alkaline Phosphatase Via an Advanced Chemometric Model. Journal of Fluorescence. 2024. doi:10.1007/s10895-023-03445-3

BibTeX
@article{Chen2024,
  author = {Chen, Yao and Han, Jing-Jing and Li, Bo-Wen and Nie, Li-Bo and Tang, Ying and Wang, Tong},
  title = {A Ratiometric Fluorescence Biosensor for Detection of Alkaline Phosphatase Via an Advanced Chemometric Model},
  journal = {Journal of Fluorescence},
  year = {2024},
  doi = {10.1007/s10895-023-03445-3}
}
Kostenlos starten →