Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2026. Verfasst von Büşra Pekince und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonology, Division of Critical Care, Konya Numune Hospital, Konya, Turkey. dr.bustek@gmail.com. Hauptthemen laut MEDLINE: Optic Nerve, Carbon Dioxide, Lung, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to compare optic nerve sheath diameter (ONSD) measurements obtained during hypercapnic and normocapnic periods in mechanically ventilated patients and to describe changes in ONSD in relation to ventilation-associated carbon dioxide levels. The study included sixty intubated patients admitted to the intensive care unit with a diagnosis of pneumonia and who underwent mechanical ventilation. ONSD measurements were performed during periods of hypercapnia identified during routine monitoring. After adjustment of ventilator settings, arterial blood gas analysis (ABG) was obtained one hour later, and ONSD measurements were repeated when normocapnia was achieved. The mean age of the patients was 61.6 ± 17.9 years. During the hypercapnic period, the mean ONSD (average of both eyes) was 4.88 ± 0.31 mm. Following the achievement of normocapnia, the mean ONSD decreased significantly to 4.61 ± 0.24 mm (p < 0.001). Furthermore, a significant positive correlation was found between the change (∆) in PaCO2 and the reduction in mean ONSD (r = 0.538, p < 0.001). ONSD measurements differed significantly between hypercapnic and normocapnic periods defined by PaCO₂ levels. These findings suggest that ONSD may reflect physiological responses across different ventilatory CO₂ states.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic NerveCarbon DioxideLungBrainHumansHypercapniaFemaleMiddle AgedMaleBlood Gas AnalysisProspective StudiesRespiration, ArtificialMonitoring, PhysiologicAgedIntensive Care UnitsPneumoniaUltrasonography

Stichwörter der Autor:innen

Cerebrovascular reactivityHypercapniaMechanical ventilationOcular ultrasonography

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Department of Pulmonology, Division of Critical Care, Konya Numune Hospital, Konya, Turkey. dr.bustek@gmail.com.
  • Department of Anesthesiology and Reanimation, Division of Critical Care, Selçuk University Faculty of Medicine, Konya, Turkey.
  • Department of Anesthesiology and Reanimation, Division of Critical Care, University of Health Sciences Beyhekim Training and Research Hospital, Konya, Turkey.
  • Department of Neurology, Division of Critical Care, University of Health Sciences Konya City Hospital, Konya, Turkey.

Zitieren

APA

Pekince, B., Bayraktar, Y. Ş., Cebeci, Y., Güngör, D. C., & Çelik, J. B. (2026). Dynamic response of optic nerve sheath diameter to PaCO2 fluctuations: A prospective clinical monitoring study of the lung-brain axis. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-026-01447-7

Vancouver

Pekince B, Bayraktar YŞ, Cebeci Y, Güngör DC, Çelik JB. Dynamic response of optic nerve sheath diameter to PaCO2 fluctuations: A prospective clinical monitoring study of the lung-brain axis. Journal of Clinical Monitoring and Computing. 2026. doi:10.1007/s10877-026-01447-7

BibTeX
@article{Pekince2026,
  author = {Pekince, Büşra and Bayraktar, Yeşim Şerife and Cebeci, Yasemin and Güngör, Dilara Cari and Çelik, Jale Bengi},
  title = {Dynamic response of optic nerve sheath diameter to PaCO2 fluctuations: A prospective clinical monitoring study of the lung-brain axis},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2026},
  doi = {10.1007/s10877-026-01447-7}
}
Kostenlos starten →