Comment on: ‘presentation of a novel method to estimate analog mean systemic filling pressure based on cardiac power’ —on correlation, coupling, and physiological meaning
Journal of Clinical Monitoring and Computing · 2025
DOI: 10.1007/s10877-025-01347-2 ↗Kurz gefasst
Leserbrief in der Zeitschrift Journal of Clinical Monitoring and Computing, 2025. Verfasst von Sebastián Faúndez und 2 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago Centro, Chile. Hauptthemen laut MEDLINE: Heart. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 1 Literaturangaben.
Abstract (Originalsprache)
In response to the recent proposal by Monares-Zepeda et al. to estimate mean systemic filling pressure (MSFP) using cardiac power (CP) as a surrogate for the venous return pressure gradient (VRg), we raise concerns regarding the physiological validity and generalizability of the reported correlation. We demonstrate through simulation that the relationship between CP and VRg arises from structural mathematical coupling due to shared dependence on cardiac output (CO), and that this correlation weakens significantly (r = 0.54) when realistic physiological variability is introduced. We further argue that CP and VRg reflect distinct hemodynamic domains, and caution against interpreting their empirical correlation as evidence of physiological interchangeability. We call for broader validation of the model across diverse circulatory conditions. Comment on: 'Presentation of a novel method to estimate analog mean systemic filling pressure based on cardiac power' -on Correlation, Coupling, and Physiological Meaning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago Centro, Chile.
- Hospital Clínico UC-CHRISTUS, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago Centro, Chile. rcastrol@uc.cl.
- Hospital Clínico UC-CHRISTUS, Pontificia Universidad Católica de Chile, Santiago, Chile. rcastrol@uc.cl.
- Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Av. Diagonal Paraguay #362 piso 6 +56 9, Santiago Centro, 7398 6588, 8330049, RM, Chile. rcastrol@uc.cl.
ORCID-Profile: Ricardo Castro
Zitieren
APA
Faúndez, S., López, P., & Castro, R. (2025). Comment on: ‘presentation of a novel method to estimate analog mean systemic filling pressure based on cardiac power’ —on correlation, coupling, and physiological meaning. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-025-01347-2
Vancouver
Faúndez S, López P, Castro R. Comment on: ‘presentation of a novel method to estimate analog mean systemic filling pressure based on cardiac power’ —on correlation, coupling, and physiological meaning. Journal of Clinical Monitoring and Computing. 2025. doi:10.1007/s10877-025-01347-2
BibTeX
@article{Fandez2025,
author = {Faúndez, Sebastián and López, Patricio and Castro, Ricardo},
title = {Comment on: ‘presentation of a novel method to estimate analog mean systemic filling pressure based on cardiac power’ —on correlation, coupling, and physiological meaning},
journal = {Journal of Clinical Monitoring and Computing},
year = {2025},
doi = {10.1007/s10877-025-01347-2}
}
EUVIMED