EUVIMEDEUVIMED entdecken
Crossref

Continuous measurement of carotid-femoral pulse wave velocity (PWVcf.) during general anaesthesia using Doppler: a preliminary study

Théophile Harlé, Jona Joachim, Pierre Boutouyrie, Joaquim Mateo, Jade Perdereau, Alexandre Mebazaa, Jérome Cartailler, Fabrice Vallée

Journal of Clinical Monitoring and Computing · 2025

DOI: 10.1007/s10877-024-01256-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2025. Verfasst von Théophile Harlé und 7 weiteren Autor:innen. Beteiligte Einrichtung: Université Paris Cité, Inserm UMRS 942 Mascot, Paris, F-75006, France. theophile.harle@gmail.com. Hauptthemen laut MEDLINE: Anesthesia, General, Carotid-Femoral Pulse Wave Velocity, Ultrasonography, Doppler, Monitoring, Intraoperative. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study explores the feasibility of continuous pulse wave velocity (PWV) monitoring during general anaesthesia (GA), particularly in response to blood pressure fluctuations. Our aim is to evaluate whether dynamic PWV can provide new insight to detect cardiovascular risks. From December 2022 to February 2023, continuous carotid and femoral Doppler monitoring was performed on patients scheduled for surgery with GA, to collect PWV data at awakening (PWVAW) and during GA (PWVGA). The study investigated PWV's response to MAP fluctuations using the α-angle, a dynamic stiffness parameter. We evaluated PWV and α-angle efficacy in discriminating between low (CVR-) and high (CVR+) cardiovascular risk patients. Among 43 patients, 41 (95%) had successful PWV measurements. PWVAW was significantly higher than PWVGA (8.1 vs. 7.4 m.s-1, p < 0.0001). This difference vanished after matching MAP levels. A strong correlation was found between PWVAW and PWVGA (r = 0.88, and r = 0.97 at the same MAP levels). PWVGA, α-angle and their product (α x PWVGA) were significantly higher in CVR + patients (8.1 vs. 6.9 m.s-1, p < 0.01; 2.6 vs. 1.3 degrees, p < 0.001; 21.8 vs. 8.1 degrees.m.s-1, p < 0.001, respectively), with AUC values indicating good predictive capabilities for cardiovascular risk (PWVGA: AUC [95%CI] = 0.80 [0.65-0.95]; α-angle: 0.83 [0.69-0.96]; product: 0.86 [0.74-0.97]). Measurement of PWV under GA using carotid and femoral Doppler is a feasible method to continuously assess arterial stiffness under general anaesthesia. Further studies are required to validate the α-angle parameter in different physiological conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anesthesia, GeneralCarotid-Femoral Pulse Wave VelocityUltrasonography, DopplerMonitoring, IntraoperativeFemoral ArteryCarotid ArteriesPulse Wave AnalysisHumansMaleFemaleMiddle AgedAgedBlood PressureCardiovascular DiseasesVascular StiffnessAdultFeasibility Studies

Stichwörter der Autor:innen

Doppleranaesthesiaarterial stiffnesspulse wave velocity

Autor:innen und Institutionen

  • Université Paris Cité, Inserm UMRS 942 Mascot, Paris, F-75006, France. theophile.harle@gmail.com.
  • Department of Anesthesia and Critical Care, Lariboisière Hospital, APHP, Paris, F-75010, France. theophile.harle@gmail.com.
  • Université Paris Cité, Inserm UMRS 942 Mascot, Paris, F-75006, France.
  • Department of Anesthesia and Critical Care, Lariboisière Hospital, APHP, Paris, F-75010, France.
  • Pharmacology, Inserm PARCC U970, Georges-Pompidou European Hospital, Paris-Cité University, Assistance publique-Hôpitaux de Paris, Paris, France.

Zitieren

APA

Harlé, T., Joachim, J., Boutouyrie, P., Mateo, J., Perdereau, J., Mebazaa, A., Cartailler, J., & Vallée, F. (2025). Continuous measurement of carotid-femoral pulse wave velocity (PWVcf.) during general anaesthesia using Doppler: a preliminary study. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01256-w

Vancouver

Harlé T, Joachim J, Boutouyrie P, Mateo J, Perdereau J, Mebazaa A, et al. Continuous measurement of carotid-femoral pulse wave velocity (PWVcf.) during general anaesthesia using Doppler: a preliminary study. Journal of Clinical Monitoring and Computing. 2025. doi:10.1007/s10877-024-01256-w

BibTeX
@article{Harl2025,
  author = {Harlé, Théophile and Joachim, Jona and Boutouyrie, Pierre and Mateo, Joaquim and Perdereau, Jade and Mebazaa, Alexandre and Cartailler, Jérome and Vallée, Fabrice},
  title = {Continuous measurement of carotid-femoral pulse wave velocity (PWVcf.) during general anaesthesia using Doppler: a preliminary study},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2025},
  doi = {10.1007/s10877-024-01256-w}
}
Kostenlos starten →