Evaluation of decision support to wean patients from mechanical ventilation in intensive care: a prospective study reporting clinical and physiological outcomes
Journal of Clinical Monitoring and Computing · 2024
DOI: 10.1007/s10877-024-01231-5 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Marcela P Vizcaychipi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Magill Department of Anaesthesia and Intensive Care Medicine, Chelsea and Westminster Hospital, APMIC, Surgery & Cancer, Imperial College London, Lon…. Hauptthemen laut MEDLINE: Ventilator Weaning, Respiration, Artificial, Critical Care, Decision Support Systems, Clinical. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Aalborg University.
Themen: Beatmung und Weaning, Intensivpflege
Abstract (Originalsprache)
This study investigated the clinical and physiological response to use of the BEACON Caresystem, a bedside open-loop decision support system providing advice to guide clinicians when weaning patients from invasive mechanical ventilation. Multicenter prospective study conducted in five adult intensive care units in the UK. Following screening and assent, intubated patients mechanically ventilated for > 24 h were randomized to intervention or usual care. Intervention consisted of application of the BEACON Caresystem’s advice on tidal volume/inspiratory pressure, inspired oxygen, respiratory rate and PEEP. Usual care was defined as local clinical practice. The primary outcome was duration of mechanical ventilation. Secondary outcomes quantified prolonged intubation and survival; adverse events; ventilator settings and physiological state; time spent in ventilator modes; links to other therapy; the frequency of advice utilization and time spent outside normal physiological limits. The study was terminated early with a total of 112 patients included. Fifty-four were randomised to the intervention arm and fifty-eight to usual care. The study was underpowered and no significant differences were seen in duration of mechanical ventilation (p = 0.773), prolonged intubation or survival. Intervention arm patients had lower rates of adverse events (p = 0.016), including fewer hypoxaemic events (p = 0.008) and lower values of PEEP (p = 0.030) and tidal volume (p = 0.042). Values of peak inspiratory pressure and pressure support were reduced but at the boarder of statistical significance (p = 0.104, p = 0.093, respectively). No differences were seen for time in ventilator mode or other therapy. Advice presented by the decision support system was applied at the beside an average of 88% of occasions, with a significantly increased number of changes only in inspired oxygen fraction. No significant differences were seen in time spent outside physiological limits. This study investigated the use of the BEACON Caresystem, an open loop clinical decision support system providing advice on ventilator settings. It was terminated early, with no significant difference shown in duration of mechanical ventilation, the primary outcome. Application of advice indicated potential for fewer adverse events and improved physiological status. ( Trial registration ClinicalTrials.gov under NCT03249623. Registered 22nd June 2017)
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Magill Department of Anaesthesia and Intensive Care Medicine, Chelsea and Westminster Hospital, APMIC, Surgery & Cancer, Imperial College London, London, UK.
- Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
- Research and Development Delivery Team, Chelsea & Westminster Hospital, London, UK.
- Intensive Care Unit, West Middlesex University Hospital, London, UK.
- Intensive Care Unit, North Middlesex University Hospital, London, UK.
- Norwich and Norfolk University Hospital Foundation Trust, Norwich, UK.
Förderung
- Aalborg University
Zitieren
APA
Vizcaychipi, M. P., Karbing, D. S., Martins, L., Gupta, A., Moreno-Cuesta, J., Naik, M., Welters, I., Singh, S., Randell, G., Osman, L., & Rees, S. E. (2024). Evaluation of decision support to wean patients from mechanical ventilation in intensive care: a prospective study reporting clinical and physiological outcomes. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01231-5
Vancouver
Vizcaychipi MP, Karbing DS, Martins L, Gupta A, Moreno-Cuesta J, Naik M, et al. Evaluation of decision support to wean patients from mechanical ventilation in intensive care: a prospective study reporting clinical and physiological outcomes. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01231-5
BibTeX
@article{Vizcaychipi2024,
author = {Vizcaychipi, Marcela P and Karbing, Dan S and Martins, Laura and Gupta, Amandeep and Moreno-Cuesta, Jeronimo and Naik, Manu and Welters, Ingeborg and Singh, Suveer and Randell, Georgina and Osman, Leyla and Rees, Stephen E},
title = {Evaluation of decision support to wean patients from mechanical ventilation in intensive care: a prospective study reporting clinical and physiological outcomes},
journal = {Journal of Clinical Monitoring and Computing},
year = {2024},
doi = {10.1007/s10877-024-01231-5}
}
EUVIMED