EUVIMEDEUVIMED entdecken
Klinische Studie

Agreement between manual and automatic ultrasound measurement of the velocity–time integral in the left ventricular outflow tract in intensive care patients: evaluation of the AUTO-VTI® tool

Benjamin Louart, Laurent Muller, Baptiste Emond, Nicolas Boulet, Claire Roger

Journal of Clinical Monitoring and Computing · 2024

DOI: 10.1007/s10877-024-01215-5 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Benjamin Louart und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care, Pain and Emergency Medicine, Nîmes-Caremeau University Hospital, Place du Professeur Robert Debré, C…. Hauptthemen laut MEDLINE: Critical Care, Echocardiography, Heart Ventricles. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transthoracic echocardiography is widely used in intensive care unit (ICU) to manage patients with acute circulatory failure. Recently, automated ultrasound (US) measurement applications have been developed but their clinical performance has not been evaluated yet. The aim of this study was to assess the agreement between automated and manual measurements of the velocity-time integral in the left ventricular outflow tract (VTI-LVOT) using the auto-VTI® tool. This prospective, single-center, interventional study included ICU patients with acute circulatory failure. The examination involved two successive manual measurements of VTI-LVOT (mean of 3 consecutive heartbeats in regular sinus rhythm, and 5 heartbeats in irregular rhythm), followed by a measurement using auto-VTI® software. In patients receiving a fluid challenge, trending ability in detecting fluid responsiveness was also evaluated. Seventy patients were included between January 19, 2020, and September 24, 2020, at the Nîmes University Hospital. The feasibility of the auto-VTI® was 94%. The mean difference between the two methods was 11% with limits of agreement from - 19% to 42%. The proportion of agreement at the 15% difference threshold was 68% [58%; 80%]. The precision and least significant change measured for the manual measurement of VTI were 7.4 and 10.5%, respectively, and by inference for the automated method 28% and 40%. The new auto-VTI® tool, despite interesting feasibility, demonstrated an insufficient agreement with a systematic bias and an insufficient precision limiting its implementation in critically ill patients.Clinical trial registration: ClinicalTrials.gov identifier: NCT04360304.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Critical CareEchocardiographyHeart VentriclesAgedAged, 80 and overFemaleHumansMaleMiddle AgedAutomationFluid TherapyIntensive Care UnitsProspective StudiesReproducibility of ResultsSoftwareUltrasonographyVentricular Function, Left

Stichwörter der Autor:innen

Acute circulatory failureArtificial intelligenceEchocardiographyInferior vena cava diameterVelocity–time integral in the left ventricular outflow tract

Autor:innen und Institutionen

  • Department of Anesthesiology and Intensive Care, Pain and Emergency Medicine, Nîmes-Caremeau University Hospital, Place du Professeur Robert Debré, CEDEX 9, 30029, Nîmes, France. benjamin.louart@chu-nimes.fr.
  • Department of Anesthesiology and Intensive Care, Pain and Emergency Medicine, Nîmes-Caremeau University Hospital, Place du Professeur Robert Debré, CEDEX 9, 30029, Nîmes, France.

Zitieren

APA

Louart, B., Muller, L., Emond, B., Boulet, N., & Roger, C. (2024). Agreement between manual and automatic ultrasound measurement of the velocity–time integral in the left ventricular outflow tract in intensive care patients: evaluation of the AUTO-VTI® tool. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01215-5

Vancouver

Louart B, Muller L, Emond B, Boulet N, Roger C. Agreement between manual and automatic ultrasound measurement of the velocity–time integral in the left ventricular outflow tract in intensive care patients: evaluation of the AUTO-VTI® tool. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01215-5

BibTeX
@article{Louart2024,
  author = {Louart, Benjamin and Muller, Laurent and Emond, Baptiste and Boulet, Nicolas and Roger, Claire},
  title = {Agreement between manual and automatic ultrasound measurement of the velocity–time integral in the left ventricular outflow tract in intensive care patients: evaluation of the AUTO-VTI® tool},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2024},
  doi = {10.1007/s10877-024-01215-5}
}
Kostenlos starten →