Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation
Journal of Clinical Monitoring and Computing · 2024
DOI: 10.1007/s10877-024-01182-x ↗Kurz gefasst
Leserbrief in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Marco Giani und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Positive-Pressure Respiration, Respiration, Artificial, Respiratory Distress Syndrome. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Airway closure is a interruption of communication between larger and smaller airways. The presence of airway closure during mechanical ventilation may lead to the overestimation of driving pressure (DP), introducing errors in the assessment of respiratory mechanics and in positive end-expiratory pressure (PEEP) setting on the ventilator. Patients with severe acute respiratory distress syndrome (ARDS) may exhibit the airway closure phenomenon, which can be easily diagnosed with a low-flow inflation. Prone positioning is a therapeutic manoeuver proven to reduce mortality in ARDS patients, and has been widely implemented also in patients requiring veno-venous extracorporeal membrane oxygenation (V-V ECMO). To date, the impact of prone positioning on changes in airway closure has not been described. METHODS: We present an image analysis of the pressure waveform during volume-controlled ventilation and low-flow inflations before and after prone positioning in an ARDS patient on VV ECMO. RESULTS: A high airway opening pressure level (23 cmH2O) was detected in the supine position during tidal ventilation. Airway closure was confirmed by using a low-flow inflation. Prone positioning significantly attenuated airway closure, with the airway opening pressure decreasing to 13 cmH2O. After re-supination, airway closure was lower as compared with supine position at baseline (17 cmH2O). CONCLUSION: Prone positioning reduced airway closure in an ARDS patient on VV ECMO support.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy.
- Department of Emergency and Intensive Care, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy.
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Canada.
- Department of Medicine, Division of Respirology, University Health Network/Sinai Health System, University of Toronto, Toronto, Canada.
- Toronto General Hospital, Toronto, Canada.
- Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, Unity Health Toronto, Toronto, Canada.
ORCID-Profile: Marco Giani, Andrea Restivo, Davide Raimondi Cominesi, Matteo Pozzi, Giuseppe Foti, Emanuele Rezoagli
Zitieren
APA
Giani, M., Restivo, A., Raimondi Cominesi, D., Fracchia, R., Pozzi, M., Del Sorbo, L., Foti, G., Brochard, L., & Rezoagli, E. (2024). Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01182-x
Vancouver
Giani M, Restivo A, Raimondi Cominesi D, Fracchia R, Pozzi M, Del Sorbo L, et al. Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01182-x