The Optimal pressure reactivity index range is disease-specific: A comparison between aneurysmal subarachnoid hemorrhage and traumatic brain injury
Journal of Clinical Monitoring and Computing · 2024-10 · 38 (5) · 1089-1099
DOI: 10.1007/s10877-024-01168-9 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Clinical Monitoring and Computing, online erschienen am 04.05.2024. Verfasst von Teodor Svedung Wettervik und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Sciences, Section of Neurosurgery, Uppsala University, 751 85, Uppsala, Sweden. teodor.svedung-wettervik@neuro.uu.se. Hauptthemen laut MEDLINE: Brain Injuries, Traumatic, Subarachnoid Hemorrhage, Cerebrovascular Circulation. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Akademiska Sjukhuset, Uppsala University.
Abstract (Originalsprache)
Purpose
Impaired cerebral pressure autoregulation is common and detrimental after acute brain injuries. Based on the prevalence of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage (aSAH) patients compared to traumatic brain injury (TBI), we hypothesized that the type of autoregulatory disturbance and the optimal PRx range may differ between these two conditions. The aim of this study was to determine the optimal PRx ranges in relation to functional outcome following aSAH and TBI, respectively.
Methods
In this observational study, 487 aSAH patients and 413 TBI patients, treated in the neurointensive care, Uppsala, Sweden, between 2008 and 2018, were included. The percentage of good monitoring time (%GMT) of PRx was calculated within 8 intervals covering the range from -1.0 to + 1.0, and analyzed in relation to favorable outcome (GOS-E 5 to 8).
Results
In multiple logistic regressions, a higher %GMTs of PRx in the intervals -1.0 to -0.5 and + 0.75 to + 1.0 were independently associated with a lower rate of favorable outcome in the aSAH cohort. In a similar analysis in the TBI cohort, only positive PRx in the interval + 0.75 to + 1.0 was independently associated with a lower rate of favorable outcome.
Conclusion
Extreme PRx values in both directions were unfavorable in aSAH, possibly as high PRx could indicate proximal vasospasm with exhausted distal vasodilatory reserve, while very negative PRx could reflect myogenic hyperreactivity with suppressed cerebral blood flow. Only elevated PRx was unfavorable in TBI, possibly as pressure passive vessels may be a more predominant pathomechanism in this disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Sciences, Section of Neurosurgery, Uppsala University, 751 85, Uppsala, Sweden. teodor.svedung-wettervik@neuro.uu.se.
- Department of Medical Sciences, Section of Neurosurgery, Uppsala University, 751 85, Uppsala, Sweden.
Förderung
- Akademiska Sjukhuset
- Uppsala University
Zitieren
APA
Svedung Wettervik, T., Howells, T., Hånell, A., Lewén, A., & Enblad, P. (2024). The Optimal pressure reactivity index range is disease-specific: A comparison between aneurysmal subarachnoid hemorrhage and traumatic brain injury. Journal of Clinical Monitoring and Computing, 38(5), 1089-1099. https://doi.org/10.1007/s10877-024-01168-9
Vancouver
Svedung Wettervik T, Howells T, Hånell A, Lewén A, Enblad P. The Optimal pressure reactivity index range is disease-specific: A comparison between aneurysmal subarachnoid hemorrhage and traumatic brain injury. Journal of Clinical Monitoring and Computing. 2024;38(5):1089-1099. doi:10.1007/s10877-024-01168-9
BibTeX
@article{SvedungWettervik2024,
author = {Svedung Wettervik, Teodor and Howells, Timothy and Hånell, Anders and Lewén, Anders and Enblad, Per},
title = {The Optimal pressure reactivity index range is disease-specific: A comparison between aneurysmal subarachnoid hemorrhage and traumatic brain injury},
journal = {Journal of Clinical Monitoring and Computing},
year = {2024},
volume = {38},
number = {5},
pages = {1089--1099},
doi = {10.1007/s10877-024-01168-9}
}
EUVIMED