Comparison of automated and manual control methods in minimal flow anesthesia
Journal of Clinical Monitoring and Computing · 2024-10 · 38 (5) · 1117-1123
DOI: 10.1007/s10877-024-01163-0 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Clinical Monitoring and Computing, online erschienen am 25.04.2024. Verfasst von Rezan Şerefoğlu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Anesthesiology and Reanimation Depertmant, Sakarya University, Sakarya, Turkey. rezzan.ozcalimli@gmail.com. Hauptthemen laut MEDLINE: Anesthetics, Inhalation, Anesthesia, Inhalation, Automation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Sakarya Üniversitesi.
Abstract (Originalsprache)
PURPOSE: New-generation anesthesia machines administer inhalation anesthetics and automatically control the fresh gas flow (FGF) rate. This study compared the administration of minimal flow anesthesia (MFA) using the automatically controlled anesthesia (ACA) module of the Mindray A9 (Shenzhen, China) anesthesia machine versus manual control by an anesthesiologist. METHODS: We randomly divided 76 patients undergoing gynecological surgery into an ACA group (Group ACA) and a manually controlled anesthesia group (Group MCA). In Group MCA, induction was performed with a mixture of 40-60% O2 and air with a 4 L/min FGF until the minimum alveolar concentration (MAC) reached 1. Next, MFA was initiated with 0.5 L/min FGF. The target fraction of inspired oxygen (FiO2) value was 35-40%. In Group ACA, the MAC was defined as 1, and the FiO2 was adjusted to 35%. Depth of anesthesia, anesthetic agent (AA) consumption, time to achieve target end-tidal AA concentration, awakening times, and number of ventilator adjustments were analyzed. RESULTS: The two groups showed no statistically significant differences in depth of anesthesia or AA consumption (Group ACA: 19.1 ± 4.9 ml; Group MCA: 17.2 ± 4.5; p-value = 0.076). The ACA mode achieved the MAC target of 1 significantly faster (Group ACA: 218 ± 51 s; Group MCA: 314 ± 169 s). The number of vaporizer adjustments was 15 in the ACA group and 217 in the MCA group. CONCLUSION: The ACA mode was more advantageous than the MCA mode, reaching target AA concentrations faster and requiring fewer adjustments to achieve a constant depth of anesthesia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Medicine, Anesthesiology and Reanimation Depertmant, Sakarya University, Sakarya, Turkey. rezzan.ozcalimli@gmail.com.
- Faculty of Medicine, Anesthesiology and Reanimation Depertmant, Sakarya University, Sakarya, Turkey.
Förderung
- Sakarya Üniversitesi
Zitieren
APA
Şerefoğlu, R., Kocayiğit, H., Palabıyık, O., & Tuna, A. T. (2024). Comparison of automated and manual control methods in minimal flow anesthesia. Journal of Clinical Monitoring and Computing, 38(5), 1117-1123. https://doi.org/10.1007/s10877-024-01163-0
Vancouver
Şerefoğlu R, Kocayiğit H, Palabıyık O, Tuna AT. Comparison of automated and manual control methods in minimal flow anesthesia. Journal of Clinical Monitoring and Computing. 2024;38(5):1117-1123. doi:10.1007/s10877-024-01163-0
BibTeX
@article{erefolu2024,
author = {Şerefoğlu, Rezan and Kocayiğit, Havva and Palabıyık, Onur and Tuna, Ayça Taş},
title = {Comparison of automated and manual control methods in minimal flow anesthesia},
journal = {Journal of Clinical Monitoring and Computing},
year = {2024},
volume = {38},
number = {5},
pages = {1117--1123},
doi = {10.1007/s10877-024-01163-0}
}
EUVIMED