Übersichtsarbeit in der Zeitschrift Journal of Clinical Monitoring and Computing, online erschienen am 21.03.2024. Verfasst von Stefano Romagnoli und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Science, Section of Anesthesia and Critical Care, Department of Anesthesia and Critical Care, University of Florence, Azienda Os…. Hauptthemen laut MEDLINE: Electroencephalography, Brain, Ultrasonography, Doppler, Transcranial, Spectroscopy, Near-Infrared. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Firenze.
Abstract (Originalsprache)
Technologies for monitoring organ function are rapidly advancing, aiding physicians in the care of patients in both operating rooms (ORs) and intensive care units (ICUs). Some of these emerging, minimally or non-invasive technologies focus on monitoring brain function and ensuring the integrity of its physiology. Generally, the central nervous system is the least monitored system compared to others, such as the respiratory, cardiovascular, and renal systems, even though it is a primary target in most therapeutic strategies. Frequently, the effects of sedatives, hypnotics, and analgesics are entirely unpredictable, especially in critically ill patients with multiple organ failure. This unpredictability exposes them to the risks of inadequate or excessive sedation/hypnosis, potentially leading to complications and long-term negative outcomes. The International PRactice On TEChnology neuro-moniToring group (I-PROTECT), comprised of experts from various fields of clinical neuromonitoring, presents this document with the aim of reviewing and standardizing the primary non-invasive tools for brain monitoring in anesthesia and intensive care practices. The focus is particularly on standardizing the nomenclature of different parameters generated by these tools. The document addresses processed electroencephalography, continuous/quantitative electroencephalography, brain oxygenation through near-infrared spectroscopy, transcranial Doppler, and automated pupillometry. The clinical utility of the key parameters available in each of these tools is summarized and explained. This comprehensive review was conducted by a panel of experts who deliberated on the included topics until a consensus was reached. Images and tables are utilized to clarify and enhance the understanding of the clinical significance of non-invasive neuromonitoring devices within these medical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Health Science, Section of Anesthesia and Critical Care, Department of Anesthesia and Critical Care, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy. stefano.romagnoli@un…
- Anesthesiology Institute, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE.
- Department of Anesthesia and Intensive Care, Edoardo Picetti, Parma University Hospital, Parma, Italy.
- Neuroanesthesia and Neurocritical Care Unit, Spedali Civili University affiliated hospital of Brescia, Brescia, Italy.
- IRCCS Policlinico San Martino, Genova, Italy.
- Dipartimento di Scienze Chirurgiche Diagnostiche ed Integrate, Università di Genova, Genova, Italy.
ORCID-Profile: Stefano Romagnoli, Francisco A Lobo
Förderung
- Università degli Studi di Firenze
Zitieren
APA
Romagnoli, S., Lobo, F. A., Picetti, E., Rasulo, F. A., Robba, C., & Matta, B. (2024). Non-invasive technology for brain monitoring: definition and meaning of the principal parameters for the International PRactice On TEChnology neuro-moniToring group (I-PROTECT). Journal of Clinical Monitoring and Computing, 38(4), 827-845. https://doi.org/10.1007/s10877-024-01146-1
Vancouver
Romagnoli S, Lobo FA, Picetti E, Rasulo FA, Robba C, Matta B. Non-invasive technology for brain monitoring: definition and meaning of the principal parameters for the International PRactice On TEChnology neuro-moniToring group (I-PROTECT). Journal of Clinical Monitoring and Computing. 2024;38(4):827-845. doi:10.1007/s10877-024-01146-1
BibTeX
@article{Romagnoli2024,
author = {Romagnoli, Stefano and Lobo, Francisco A and Picetti, Edoardo and Rasulo, Frank A and Robba, Chiara and Matta, Basil},
title = {Non-invasive technology for brain monitoring: definition and meaning of the principal parameters for the International PRactice On TEChnology neuro-moniToring group (I-PROTECT)},
journal = {Journal of Clinical Monitoring and Computing},
year = {2024},
volume = {38},
number = {4},
pages = {827--845},
doi = {10.1007/s10877-024-01146-1}
}
EUVIMED