EUVIMEDEUVIMED entdecken
Crossref

Electronic health record data is unable to effectively characterize measurement error from pulse oximetry: a simulation study

Elie Sarraf iD

Journal of Clinical Monitoring and Computing · 2024

DOI: 10.1007/s10877-024-01131-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Elie Sarraf. Beteiligte Einrichtung: Department of Anesthesiology and Perioperative Medicine, Penn State College of Medicine, 500 University Drive Mail Code, H187, Hershey, PA, 17033, US…. Hauptthemen laut MEDLINE: Oximetry, Electronic Health Records, Computer Simulation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Large data sets from electronic health records (EHR) have been used in journal articles to demonstrate race-based imprecision in pulse oximetry (SpO2) measurements. These articles do not appear to recognize the impact of the variability of the SpO2 values with respect to time ("deviation time"). This manuscript seeks to demonstrate that due to this variability, EHR data should not be used to quantify SpO2 error. Using the MIMIC-IV Waveform dataset, SpO2 values are sampled from 198 patients admitted to an intensive care unit and used as reference samples. The error derived from the EHR data is simulated using a set of deviation times. The laboratory oxygen saturation measurements are also simulated such that the performance of three simulated pulse oximeter devices will produce an average root mean squared (ARMS) error of 2%. An analysis is then undertaken to reproduce a medical device submission to a regulatory body by quantifying the mean error, the standard deviation of the error, and the ARMS error. Bland-Altman plots were also generated with their Limits of Agreements. Each analysis was repeated to evaluate whether the measurement errors were affected by increasing the deviation time. All error values increased linearly with respect to the logarithm of the time deviation. At 10 min, the ARMS error increased from a baseline of 2% to over 4%. EHR data cannot be reliably used to quantify SpO2 error. Caution should be used in interpreting prior manuscripts that rely on EHR data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OximetryElectronic Health RecordsComputer SimulationHumansReproducibility of ResultsIntensive Care UnitsOxygen SaturationMonitoring, PhysiologicAlgorithmsOxygen

Stichwörter der Autor:innen

Electronic health dataMeasurement errorPulse oximetryStochastic process

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Anesthesiology and Perioperative Medicine, Penn State College of Medicine, 500 University Drive Mail Code, H187, Hershey, PA, 17033, USA. dr.elsar@gmail.com.

ORCID-Profile: Elie Sarraf

Zitieren

APA

Sarraf, E. (2024). Electronic health record data is unable to effectively characterize measurement error from pulse oximetry: a simulation study. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01131-8

Vancouver

Sarraf E. Electronic health record data is unable to effectively characterize measurement error from pulse oximetry: a simulation study. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01131-8

BibTeX
@article{Sarraf2024,
  author = {Sarraf, Elie},
  title = {Electronic health record data is unable to effectively characterize measurement error from pulse oximetry: a simulation study},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2024},
  doi = {10.1007/s10877-024-01131-8}
}
Kostenlos starten →