EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Tissue requirements for the application of aortic valve neocuspidization – appropriate pericardium properties and homogeneity?

Claudia Dittfeld, Sophia Bähring, Cindy Welzel, Anett Jannasch, Klaus Matschke, Sems-Malte Tugtekin, Konstantin Alexiou

Journal of Materials Science: Materials in Medicine · 2024

DOI: 10.1007/s10856-024-06790-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Materials Science: Materials in Medicine, 2024. Verfasst von Claudia Dittfeld und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Dresden, Germany. Claudia…. Hauptthemen laut MEDLINE: Pericardium, Aortic Valve, Heart Valve Prosthesis, Bioprosthesis. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Aortic valve neocuspidization (AVNeo) using autologous pericardium is a promising technique. Expected advantages are reduced immune response, appropriate biomechanics and lower treatment expenses. Nevertheless, autologous pericardium can be affected by patient’s age and comorbidities. Usually, glutaraldehyde (GA) - fixed bovine pericardium is the basic material for aortic valve prostheses, easy available and carefully pre-examined in a standardized fabrication process. Aim of the study is the verification of autologous pericardial tissue homogeneity by analysing tissue thickness, biomechanics and extracellular matrix (ECM) composition.

Methods

Segments of human GA-fixed pericardium selected by the surgeon based on visual criteria for cusp pre-cut and remaining after surgical AV replacement were investigated in comparison to bovine standard tissue treated equivalently. Pericardium sampling was performed at up to three positions of each sutured cusp for histological or biomechanical analysis, according to tissue availability. Results and Conclusions: Human pericardia exhibited a higher heterogeneity in collagen content, density of vessel structures and elastic moduli. Thickness, vessel density and collagen and elastin content differed significantly between the species. In contrast, significant interindividual differences were detected in most properties investigated for human pericardial samples but only for tissue thickness in bovine tissues. Higher heterogeneity of human pericardium, differing vessel and collagen content compared to bovine state-of-the-art material might be detrimental for long term AV functionality or deterioration and have to be intensely investigated in patients follow up after autologous cusp replacement. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PericardiumAortic ValveHeart Valve ProsthesisBioprosthesisCattleHumansAnimalsBiomechanical PhenomenaMaleFemaleAgedExtracellular MatrixMiddle AgedCollagenGlutaralMaterials TestingHeart Valve Prosthesis Implantation

Substanzen

CollagenGlutaral

Autor:innen und Institutionen

  • Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Dresden, Germany. Claudia.Dittfeld@tu-dresden.de.
  • Department of Cardiac Surgery, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Heart Centre Dresden, Dresden, Germany.

Zitieren

APA

Dittfeld, C., Bähring, S., Welzel, C., Jannasch, A., Matschke, K., Tugtekin, S. M., & Alexiou, K. (2024). Tissue requirements for the application of aortic valve neocuspidization – appropriate pericardium properties and homogeneity?. Journal of Materials Science: Materials in Medicine. https://doi.org/10.1007/s10856-024-06790-2

Vancouver

Dittfeld C, Bähring S, Welzel C, Jannasch A, Matschke K, Tugtekin SM, et al. Tissue requirements for the application of aortic valve neocuspidization – appropriate pericardium properties and homogeneity?. Journal of Materials Science: Materials in Medicine. 2024. doi:10.1007/s10856-024-06790-2

BibTeX
@article{Dittfeld2024,
  author = {Dittfeld, Claudia and Bähring, Sophia and Welzel, Cindy and Jannasch, Anett and Matschke, Klaus and Tugtekin, Sems-Malte and Alexiou, Konstantin},
  title = {Tissue requirements for the application of aortic valve neocuspidization – appropriate pericardium properties and homogeneity?},
  journal = {Journal of Materials Science: Materials in Medicine},
  year = {2024},
  doi = {10.1007/s10856-024-06790-2}
}