EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtOpen Access · CC BY 4.0

Cardiac magnetic resonance parameters and ventricular tachycardia recurrence after catheter ablation: a systematic review and meta-analysis

Alexandru Deaconu, Amr Abdin, Mircea Ioan Alexandru Bistriceanu, Silvia Deaconu, Obaida Makdah, Saif Almaghrabi, Guido Matschuck, Cosmin Gabriel Ursu, Sebastian Onciul, Radu Gabriel Vătăsescu

Journal of Interventional Cardiac Electrophysiology · 05.08.2026 · 69 (9) · 3231-3242

DOI: 10.1007/s10840-026-02415-6 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 05.08.2026. Verfasst von Alexandru Deaconu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest, 050474, Romania. Hauptthemen laut MEDLINE: Catheter Ablation, Magnetic Resonance Imaging, Magnetic Resonance Imaging, Cine, Tachycardia, Ventricular. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Access Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cardiac magnetic resonance (CMR) may provide insights into arrhythmogenic substrate in patients undergoing ventricular tachycardia (VT) ablation, but its prognostic value remains uncertain.

Methods

We performed a systematic review and meta-analysis, following PRISMA guidelines, of available studies comparing CMR-derived parameters in patients with and without VT recurrence after ablation, from inception to March 2026. Primary outcomes included functional parameters - left ventricular ejection fraction (LVEF) and left ventricular (LV) mass, while secondary outcomes included ventricular volumes and late gadolinium enhancement (LGE) derived structural characteristics. Random-effects models were applied.

Results

Seven studies including 415 patients were analyzed, with 36.1% experiencing VT recurrence. Lower LVEF was associated with recurrence in the primary analysis (mean difference: − 4.41%; 95% CI: − 8.66 to − 0.16; p = 0.044; I²=27.3%), however, this finding was not robust in leave-one-out analysis. No significant associations were observed for LV mass or ventricular volumes. Among structural parameters, transmural, epicardial, or septal LGE were not associated with recurrence.

Conclusion

Available evidence suggests that CMR-derived parameters have limited and inconsistent associations with VT recurrence after catheter ablation. Although reduced LVEF may be associated with recurrence, this finding was not robust in sensitivity analyses, while structural CMR characteristics showed no consistent associations. Larger prospective studies using standardized CMR protocols and time-to-event analyses are needed to better define the prognostic role of CMR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationMagnetic Resonance ImagingMagnetic Resonance Imaging, CineTachycardia, VentricularHumansPrognosisRecurrenceStroke Volume

Stichwörter der Autor:innen

Cardiac magnetic resonanceCatheter ablationLate gadolinium enhancementScar characterizationVT recurrenceVentricular tachycardia

Autor:innen und Institutionen

  • Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest, 050474, Romania.
  • Clinical Electrophysiology and Pacing Laboratory Emergency Clinical Hospital, Bucharest, 014461, Romania.
  • Internal Medicine Clinic III, Cardiology, Angiology and Intensive Care Medicine, Saarland University Hospital, Homburg/Saar, 66421, Germany.
  • Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest, 050474, Romania. mircea-ioan-alexandru.bistriceanu0721@stud.umfcd.ro.
  • Monza-Ares Hospital, Bucharest, 021967, Romania. Si.deaconu@gmail.com.
  • Sana Kliniken Niederlausitz, Senftenberg, Germany.

Förderung

  • Open Access Program

Zitieren

APA

Deaconu, A., Abdin, A., Bistriceanu, M. I. A., Deaconu, S., Makdah, O., Almaghrabi, S., Matschuck, G., Ursu, C. G., Onciul, S., & Vătăsescu, R. G. (2026). Cardiac magnetic resonance parameters and ventricular tachycardia recurrence after catheter ablation: a systematic review and meta-analysis. Journal of Interventional Cardiac Electrophysiology, 69(9), 3231-3242. https://doi.org/10.1007/s10840-026-02415-6

Vancouver

Deaconu A, Abdin A, Bistriceanu MIA, Deaconu S, Makdah O, Almaghrabi S, et al. Cardiac magnetic resonance parameters and ventricular tachycardia recurrence after catheter ablation: a systematic review and meta-analysis. Journal of Interventional Cardiac Electrophysiology. 2026;69(9):3231-3242. doi:10.1007/s10840-026-02415-6

BibTeX
@article{Deaconu2026,
  author = {Deaconu, Alexandru and Abdin, Amr and Bistriceanu, Mircea Ioan Alexandru and Deaconu, Silvia and Makdah, Obaida and Almaghrabi, Saif and Matschuck, Guido and Ursu, Cosmin Gabriel and Onciul, Sebastian and Vătăsescu, Radu Gabriel},
  title = {Cardiac magnetic resonance parameters and ventricular tachycardia recurrence after catheter ablation: a systematic review and meta-analysis},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  volume = {69},
  number = {9},
  pages = {3231--3242},
  doi = {10.1007/s10840-026-02415-6}
}
Kostenlos starten →