Gastroparesis as a potential complication of pentaspline pulsed field ablation without endoscopic esophageal injury

Mourad Haj Abdo, Thomas Deneke, Karin Nentwich, Ivaylo Chakarov, Arthur Berkovitz, Elena Sauer, Martjin Rogiers, Christiane Neumann, Lisa Costello-Boerrigter, Sebastian Barth, Khalil Haj Abdo, Lepasova Mihajloska und 3 weitere

Journal of Interventional Cardiac Electrophysiology · 20.09.2025 · 69 (1) · 63-69

DOI: 10.1007/s10840-025-02130-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 20.09.2025. Verfasst von Mourad Haj Abdo und 14 weiteren Autor:innen. Beteiligte Einrichtung: Clinic for Rhythmology and Interventional Electrophysiology, Heart Center Campus Bad Neustadt, Salzburger Leite.1, 97616, Bad Neustadt an Der Saale, …. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Gastroparesis, Pulmonary Veins. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulsed field ablation (PFA) is a new nonthermal, ablation modality for pulmonary vein isolation (PVI) that is cardiac tissue selective. Compelling acute and long-term success rates and good safety features have been reported using a pentaspline PFA catheter. Thus far, no atrio-esophageal fistula (AEF) related to PFA has been reported. However, this fatal complication is rare and endoscopically detected esophageal lesions (EDEL) may serve as a more sensitive instrument to document esophageal safety. This study aimed to evaluate the esophageal safety of the Farapulse™ PFA system by systematically using upper endoscopy post-ablation in a large, single-center cohort. METHODS: Patients with symptomatic atrial fibrillation (AF) underwent PVI using the pentaspline PFA system. Additional left atrial posterior PFA application was used in some cases. All patients underwent esophageal endoscopy within 1 day post-ablation. Follow-up visits occurred 3 and 12 months post-procedure. The patients had 48 h-Holter monitoring performed before each visit. RESULTS: Consecutive, symptomatic AF patients (n = 228, 87.6% paroxysmal) were enrolled. The patients were relatively young (age 59.4 ± 11.7 years), 67.4% male, and had a normal mean left ventricular function of 60 ± 8%. Mean left atrial diameter was 41 ± 4 mm. All PVs were successfully isolated. The procedure time was 55 ± 11 min, fluoroscopy duration was 7 ± 3 min, and the median dose area product was 563 ± 410 cGy cm2. Major procedural complications were only two AV fistula, which did not require intervention. No stroke, pericardial tamponade, or phrenic nerve damage occurred. EDEL were not detected in any patient. Gastroparesis occurred in nine (4%) cases. CONCLUSIONS: The lack of EDEL post-PVI using the pentaspline PFA-catheter in this large AF cohort highlights the esophageal safety of this method. Gastroparesis was observed in a small minority, but relationship with PFA is still to be determined.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationGastroparesisPulmonary VeinsEsophagusHumansMaleFemaleMiddle AgedAgedEsophagoscopyTreatment Outcome

Stichwörter der Autor:innen

AblationAtrial fibrillationElectroporationEndoscopically detected oesophageal lesions (EDEL)GastroparesisPulsed field ablation

Autor:innen und Institutionen

  • Clinic for Rhythmology and Interventional Electrophysiology, Heart Center Campus Bad Neustadt, Salzburger Leite.1, 97616, Bad Neustadt an Der Saale, Germany. moradhajabdo86@hotmail.de.
  • Clinic for Electrophysiology, University Hospital of the Paracelsus Medical University, Klinikum Nuremberg, Bresalauerstrasse, 201 Campus South, 90471, Nuremberg, Germany.
  • Clinic for Rhythmology and Interventional Electrophysiology, Heart Center Campus Bad Neustadt, Salzburger Leite.1, 97616, Bad Neustadt an Der Saale, Germany.
  • Clinic for Internal Medicine, Campus Bad Neustadt, Salzburger Leite 1, 97616, Bad Neustadt an Der Saale, Germany.
  • Department of Cardiology, Heart Center, Zentralklinik Bad Berka and Clinical Research, Rhön Klinikum AG, Robert-Koch-Allee 9, 99437, Bad Berka, Germany.
  • Department of Cardiology, Rhythmology, Angiology and Intensive Care Medicine, Am Finkenhügel 1, Heart Center Osnabrueck, 49076, Osnabrueck, Germany.

Zitieren

APA

Haj Abdo, M., Deneke, T., Nentwich, K., Chakarov, I., Berkovitz, A., Sauer, E., Rogiers, M., Neumann, C., Costello-Boerrigter, L., Barth, S., Haj Abdo, K., Mihajloska, L., Surber, R., Lüsebrink, U., & Schade, A. (2025). Gastroparesis as a potential complication of pentaspline pulsed field ablation without endoscopic esophageal injury. Journal of Interventional Cardiac Electrophysiology, 69(1), 63-69. https://doi.org/10.1007/s10840-025-02130-8

Vancouver

Haj Abdo M, Deneke T, Nentwich K, Chakarov I, Berkovitz A, Sauer E, et al. Gastroparesis as a potential complication of pentaspline pulsed field ablation without endoscopic esophageal injury. Journal of Interventional Cardiac Electrophysiology. 2025;69(1):63-69. doi:10.1007/s10840-025-02130-8

BibTeX
@article{HajAbdo2025,
  author = {Haj Abdo, Mourad and Deneke, Thomas and Nentwich, Karin and Chakarov, Ivaylo and Berkovitz, Arthur and Sauer, Elena and Rogiers, Martjin and Neumann, Christiane and Costello-Boerrigter, Lisa and Barth, Sebastian and Haj Abdo, Khalil and Mihajloska, Lepasova and Surber, Ralf and Lüsebrink, Ulrich and Schade, Anja},
  title = {Gastroparesis as a potential complication of pentaspline pulsed field ablation without endoscopic esophageal injury},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2025},
  volume = {69},
  number = {1},
  pages = {63--69},
  doi = {10.1007/s10840-025-02130-8}
}
Kostenlos starten →