Ultrasound-guided versus fluoroscopy-guided axillary vein puncture for cardiac implantable electronic device implantation: a meta-analysis enrolling 1257 patients
Journal of Interventional Cardiac Electrophysiology · 2024
DOI: 10.1007/s10840-024-01932-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Giampaolo Vetta und 20 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brus…. Hauptthemen laut MEDLINE: Axillary Vein, Defibrillators, Implantable, Pacemaker, Artificial, Prosthesis Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Ultrasound-guided (Echo-AVP) and Fluoroscopy-guided Axillary Vein Puncture (Fluoro-AVP) are both acknowledged as safe and effective techniques for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. Therefore, we performed a meta-analysis to evaluate the efficacy and safety of Echo-AVP versus Fluoro-AVP for CIEDs implantation. METHODS: We systematically searched Medline, Embase and Cochrane electronic databases up to May 15th, 2024, for studies that evaluated the efficacy and safety of Echo-AVP and Fluoro-AVP reporting at least one clinical outcome of interest. The primary efficacy endpoint was acute procedural success and the primary safety endpoint was a composite endpoint of pneumothorax, pocket hematoma/bleeding, pocket infection and inadvertent arterial puncture. The effect size was estimated using a random-effect model as Odds Ratio (OR) and Mean Difference (MD) with relative 95% Confidence Interval (CI). RESULTS: Overall, 4 studies were included, which enrolled 1257 patients (Echo-AVP: 373 patients; Fluoro-AVP: 884 patients). Echo-AVP led to a significant reduction in the primary safety endpoint (OR: 0.41; p = 0.0009), risk of inadvertent arterial puncture (OR: 0.29; p = 0.003) and fluoroscopy time ( MD: -105.02; p = 0.008). No differences were found between Echo-AVP and Fluoro-AVP for acute procedural success (OR: 0.77; p = 0.27), pneumothorax (OR: 0.66; p = 0.60), pocket hematoma/bleeding (OR: 0.68; p = 0.30), pocket infection (OR: 0.66; p = 0.60), procedural time (MD: 1.99; p = 0.65), success rate at first attempt (OR: 1.25; p = 0.34) and venous access time (MD: -0. 25; p = 0.99). CONCLUSION: Echo-AVP proved to reduce significantly the primary safety endpoint, inadvertent arterial puncture and fluoroscopy time compared to Fluoro-AVP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.
- Mediterranean Consortium for Arrhythmia Research (MediCAR), Rome, Italy.
- Department of Clinical and Experimental Medicine, Cardiology Unit, University of Messina, Messina, Italy.
- School of Medicine and Public Health, Department of Medicine, Division of Cardiovascular Medicine, University of Wisconsin, 600 Highland Avenue, Madison, WI, 53792, USA.
- Arrhythmology Unit, Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola, Rome, Italy.
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium. domen…
Zitieren
APA
Vetta, G., Parlavecchio, A., Wright, J., Magnocavallo, M., Marcon, L., Doundoulakis, I., Scacciavillani, R., Sorgente, A., Pannone, L., Almorad, A., Sieira, J., Audiat, C., Nakasone, K., Bala, G., Ströker, E., Overeinder, I., Rossi, P., Sarkozy, A., Chierchia, G. B., …, & Della Rocca, D. G. (2024). Ultrasound-guided versus fluoroscopy-guided axillary vein puncture for cardiac implantable electronic device implantation: a meta-analysis enrolling 1257 patients. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01932-6
Vancouver
Vetta G, Parlavecchio A, Wright J, Magnocavallo M, Marcon L, Doundoulakis I, et al. Ultrasound-guided versus fluoroscopy-guided axillary vein puncture for cardiac implantable electronic device implantation: a meta-analysis enrolling 1257 patients. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01932-6
BibTeX
@article{Vetta2024,
author = {Vetta, Giampaolo and Parlavecchio, Antonio and Wright, Jennifer and Magnocavallo, Michele and Marcon, Lorenzo and Doundoulakis, Ioannis and Scacciavillani, Roberto and Sorgente, Antonio and Pannone, Luigi and Almorad, Alexandre and Sieira, Juan and Audiat, Charles and Nakasone, Kazutaka and Bala, Gezim and Ströker, Erwin and Overeinder, Ingrid and Rossi, Pietro and Sarkozy, Andrea and Chierchia, Gian-Battista and de Asmundis, Carlo and Della Rocca, Domenico Giovanni},
title = {Ultrasound-guided versus fluoroscopy-guided axillary vein puncture for cardiac implantable electronic device implantation: a meta-analysis enrolling 1257 patients},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01932-6}
}