EUVIMEDEUVIMED entdecken
Multizentrische Studie

The impact of peri-procedural imaging on safety and efficacy of atrial fibrillation ablation: insights from the Israeli AF Catheter Ablation Registry (ICAR)

Ibrahim Marai, Adi Elias, Guy Rozen, Roy Beinart, Eyal Nof, Yoav Michowitz, Michael Glikson, Yuval Konstantino, Moti Haim, David Luria, Alexander Omelchenko, Avishag Laish-Farkash und 2 weitere

Journal of Interventional Cardiac Electrophysiology · 2024

DOI: 10.1007/s10840-024-01887-8 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Ibrahim Marai und 13 weiteren Autor:innen. Beteiligte Einrichtung: Lea and Benjamin Davidai Division of Cardiovascular Medicine and Surgery, Cardiovascular Department, The Azrieli Faculty of Medicine, The Lydia and C…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulmonary vein isolation (PVI) is the most effective therapy to achieve rhythm control in atrial fibrillation (AF). Peri-procedural imaging is used in many but not all centers. However, the impact of imaging on safety and efficacy of PVI is not clear. The Israeli Catheter Ablation Registry (ICAR) is a great opportunity to explore this issue in real-world practice. AIM: To describe the real-world utilization of peri-procedural imaging technologies in a large cohort of patients undergoing ablation for AF. METHODS: A prospective-multicenter cohort of AF patients who underwent PVI during the years 2019-2021. Peri-procedural imaging (CT, ICE, TEE) was utilized based on the center and operator discretion. The study endpoints were peri-procedural complications and AF recurrence at 12 months follow-up among patients with and without peri-procedural imaging. RESULTS: Between January 2019 and December 2021, a total of 921 patients underwent PVI. Peri-procedural imaging (at least 1 modality of CT, TEE, and or ICE) was utilized in 753 (81.8%) and no imaging among 168 (18.2%) patients. Cryoablation was the dominant energy used for PVI in both groups (92.3% of the non-imaging group, and 95.3% among imaging group), while RF was used in the rest of the patients. Fluoroscopy time was not different between the 2 groups; however, procedure duration was longer among the imaging group (90 min) compared to the non-imaging group (74.5 min, p = 0.006). By 12 months, the incidence of AF recurrence and repeated ablation were not different between the groups. Complications and re-hospitalization for cardiocerebrovascular reasons were not different among the 2 groups. Cox regression model demonstrated no association between preprocedural imaging and the risk of AF recurrence after ablation. CONCLUSION: This real-world multicenter prospective registry study demonstrated that the rate of complications and the rate of recurrence of AF during 1 year follow-up were not different among patients who had PVI either with or without peri-procedural imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPulmonary VeinsHumansFemaleRegistriesMaleMiddle AgedProspective StudiesIsraelTreatment OutcomeCryosurgeryRecurrenceAgedTomography, X-Ray Computed

Stichwörter der Autor:innen

AblationAtrial fibrillationImagingPulmonary vein isolation

Autor:innen und Institutionen

  • Lea and Benjamin Davidai Division of Cardiovascular Medicine and Surgery, Cardiovascular Department, The Azrieli Faculty of Medicine, The Lydia and Carol KittnerTzafon Medical Center, PoriyaBar Ilan University, Zefat, I…
  • Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Technion, Eyal Ofer Heart Hospital, Cardiac Electrophysiology and Pacing, Haifa, Israel.
  • Heart Institute, Sheba Medical Center, Tel-Hashomer, Israel.
  • Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Jesselson Integrated Heart Center, Shaare Zedek Medical Center and Hebrew University, Jerusalem, Israel.
  • Department of Cardiology, Cardiac Electrophysiology and Pacing, Soroka University Hospital, Ben-Gurion University of the Negev, Beer-Sheva, Israel.

Zitieren

APA

Marai, I., Elias, A., Rozen, G., Beinart, R., Nof, E., Michowitz, Y., Glikson, M., Konstantino, Y., Haim, M., Luria, D., Omelchenko, A., Laish-Farkash, A., Suleiman, M., & Israeli Working Group on Pacing, Electrophysiology (2024). The impact of peri-procedural imaging on safety and efficacy of atrial fibrillation ablation: insights from the Israeli AF Catheter Ablation Registry (ICAR). Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01887-8

Vancouver

Marai I, Elias A, Rozen G, Beinart R, Nof E, Michowitz Y, et al. The impact of peri-procedural imaging on safety and efficacy of atrial fibrillation ablation: insights from the Israeli AF Catheter Ablation Registry (ICAR). Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01887-8

BibTeX
@article{Marai2024,
  author = {Marai, Ibrahim and Elias, Adi and Rozen, Guy and Beinart, Roy and Nof, Eyal and Michowitz, Yoav and Glikson, Michael and Konstantino, Yuval and Haim, Moti and Luria, David and Omelchenko, Alexander and Laish-Farkash, Avishag and Suleiman, Mahmoud and Israeli Working Group on Pacing, Electrophysiology, Israeli Working Group on Pacing, Electrophysiology},
  title = {The impact of peri-procedural imaging on safety and efficacy of atrial fibrillation ablation: insights from the Israeli AF Catheter Ablation Registry (ICAR)},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2024},
  doi = {10.1007/s10840-024-01887-8}
}
Kostenlos starten →